7. Set up LoggerNet
The LoggerNet Network Map is configured from the
LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click
on the View menu at the top of the Setup screen, and
select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure
the Network Map as described in the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort and pbRouter for PakBus data
loggers such as the CR6 or CR1000X.
NOTE:
PakBus data loggers include the following
models:GRANITE-series, CR6, CR3000, CR1000X,
CR800-series, CR300-series, CR1000, and CR200(X)-
series.
3. Add a data logger to the pbRouter.
4. From the Entire Network, on the left side, select the
IPPort. Enter the Konect PakBus Router DNS address
and port number as noted in the Konect PakBus Router
setup (Set up Konect PakBus Router (p. 2)). Enter them
into the Internet IP Address field in the format DNS:Port
with a colon separating DNS and Port. For example,
axanar.konectgds.com:pppp where pppp is the port
number.
5. Leave the default settings for the PakBusPort. PakBus
Port Always Open should not be checked. In the TCP
Password field enter the TCP Password; this must match
the value entered in the Konect PakBus Router setup
and LoggerNet setup.
6. Select the pbRouter in the Network Map and set the
PakBus Address to 4070.
7. Select the data logger in the Network Map and set the
PakBus Address to match that of the data logger
(default address in the data logger is 1). If a PakBus
Encryption Key was entered during data logger setup,
also enter it here. Click Apply to save the changes.