EasyManua.ls Logo

Canature WaterGroup 95MTS - User Manual

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation and Operation Manual
95MTS
Multi Tank Systems
Water Softener
Canature WaterGroup Canada Inc.
855 Park St., Unit 1
Regina, SK, S4N 6M1
Toll Free: (877) 288-9888
Canature WaterGroup U.S.A. Inc.
6353 Commerce Drive
Whitestown, IN, 46075
Toll Free: (877) 288-9888
Question and Answer IconNeed help?

Do you have a question about the Canature WaterGroup 95MTS and is the answer not in the manual?

Summary

Introduction to MTS Water Softeners

Standard Features and Benefits

Highlights the system's advanced design and performance advantages over traditional products.

High Efficiency and Product Water Quality

Details how the system optimizes salt and water usage for regeneration and maintains high water quality.

Optional System Enhancements

Describes optional features like Polishing Recycle Rinse, Battery Back Up, and Remote Start.

MTS95 System Configuration

Softener System Configuration Parameters

Specifies tank size, injector sets, and brine/drain line flow controls for MTS95 softeners.

Filter Valve Configuration Guidelines

Lists recommended filter valve configurations based on tank diameter for optimal performance.

Installation Instructions for MTS Systems

Unit Placement and Plumbing

Guidelines for locating the system, performing plumbing, and connecting drain lines with air gaps.

MTS System Start-Up Procedures

Keypad and Button Functions

Explains the operation of the MENU, SET/REGEN, and DOWN/UP buttons for system control.

MTS System Start-Up Procedures (Continued)

Initial Power and Valve Setup

Instructions for connecting power, data cables, and setting valve positions for regeneration.

Water Flow and Brine Tank Initialization

Steps for flushing media, checking brine draw, and ensuring proper rinse cycles.

MTS System Diagram and Components

Main Control Display Overview

Illustrates the information presented on the main controller's display screen.

Key System Component Identification

Identifies and shows the location of major components like valves, controllers, and pumps.

Programming MTS Control System

Navigating the Control Menu

Guide on using the MENU, SET, UP, and DOWN buttons to navigate system settings.

Setting Date, Time, Region, and Language

Procedures for configuring essential system parameters like date, time, region, and language.

Programming MTS Control System (Continued)

System Type Selection

How to choose the system type (Softener, Filter) and its operational modes.

Softener (Demand Flow) Operation

Explains how the softener operates based on water demand and tank sequencing.

Filter System Operational Modes

Details on Time Clock, Meter Delay, Meter Immediate, and Pressure Drop filter operations.

Programming MTS Control System (Continued)

Softener System Type Configuration

Setting up softener specifics including total units, resin volume, and refill rate.

System Size and Resin Settings

Adjusting the number of units, resin per unit, and refill flow rate (DLFC).

Salt Efficiency Configuration

Selecting High Efficiency, Standard Efficiency, or High Capacity salt settings.

Programming MTS Control System (Continued)

Feed Water Parameter Input

Entering concentrations for Hardness, Iron, and Manganese in the feed water.

Regeneration Cycle Time Settings

Customizing Backwash, Brine, Rinse, and Refill times for regeneration cycles.

Advanced Settings Overview

Introduction to advanced settings like Trip Point, Peak Period Block Out, and Auxiliary Outputs.

Programming MTS Control System (Continued)

Trip Point Settings for Tank Activation

Configuring flow rates and delay times that trigger additional tanks to come online.

Peak Period Block Out Configuration

Setting specific times of day to prevent regeneration, ensuring service continuity.

Programming MTS Control System (Continued)

Auxiliary Output Configuration

Setting up remote start switches and auxiliary relays for system control.

Salt Efficiency and Residual Settings

Adjusting salt usage efficiency and minimum residual capacity for regeneration scheduling.

Programming MTS Control System (Continued)

Chemical Pump Operation Settings

Configuring the volume and time for the chemical pump based on water flow.

Product Water Polish Function

Setting minimum flow rate and duration for the product water recycle pump.

Programming MTS Control System (Continued)

Filter System Type and Settings

Overview of different filter system types and their associated programming menus.

Programming MTS Control System (Continued)

Regeneration Time and Schedule Setup

Setting the time of day for regeneration and choosing regeneration schedule methods.

System Size and Gallon Capacity Adjustment

Modifying the total number of units and the system's gallon capacity setting.

Filter Pressure Settings

Adjusting trip point and delay for pressure-based regeneration in filter mode.

Programming MTS Control System (Continued)

Regeneration Cycle Time Adjustments

Modifying Backwash and Rinse times for all tanks in the system.

Advanced Settings Menu Access

Accessing Peak Period Block Out, Auxiliary Outputs, and Chemical Pump settings.

Peak Period Block Out Details

Explanation of how to configure periods where regeneration is not permitted.

Advanced Programming for MTS Systems

Auxiliary Outputs Overview

Introduction to configuring remote start switches and auxiliary relays.

Remote Start Switch Configuration

Detailed steps for setting up immediate, delayed, or held remote regeneration starts.

Auxiliary Relay Output Programming

Programming relay outputs for regeneration duration or specific functions like chemical pumps.

Advanced Programming for MTS Systems (Continued)

Trip Point Settings Details

Specific values for trip delay, flow rates ON/OFF for tank activation.

Auxiliary Relay Output Programming Details

Advanced configuration for relay outputs across different cycles.

Chemical Pump and Water Polish Configuration

Detailed settings for chemical pump operation and product water polishing.

Advanced Programming for MTS Systems (Continued)

Formatting Master and Slave PCBs

Procedures for formatting and resetting slave and master control boards.

Re-formatting Slave PCB Data

Erasing history data and settings from slave control boards.

Restoring Main PCB Settings

Procedures for restoring settings and history from slave PCBs to the main PCB.

MTS Wiring Schematics

Softener;Filter Wiring Diagram

General wiring diagram for connecting MTS softener or filter systems.

MTS Wiring Schematics (Continued)

Unit 1 and Unit 2 Wiring Details

Detailed wiring diagrams for master and slave controllers in multi-unit systems.

MTS Wiring Schematics (Continued)

Wiring for Polishing Recycle Option

Wiring diagram specific to systems equipped with the polishing recycle feature.

MTS Wiring Schematics (Continued)

Wiring for Pressure Differential Switch Option

Wiring diagram for filter systems utilizing a pressure differential switch.

Removing the Power Head Assembly

Manual Power Head Assembly Removal

Step-by-step guide for manually detaching the power head assembly.

Automatic Power Head Assembly Removal

Instructions for detaching the power head assembly using automatic valve movement.

Replacing Drain Line Flow Control (DLFC)

DLFC Replacement Procedure

Steps for removing and replacing the Drain Line Flow Control component.

Replacing Brine Line Flow Control (BLFC)

BLFC Replacement Procedure

Steps for removing and replacing the Brine Line Flow Control component.

Replacing or Cleaning Injectors

Injector Assembly Replacement Steps

Detailed instructions for removing and replacing injector components.

Injector Cleaning Recommendations

Guidance on cleaning injector parts, including using mild acid solutions.

MTS System Components Overview

Valve BNT950 MTS (Slave) Identification

Details and identification of the MTS slave valve unit.

Main Controller and Communication Cables

Part numbers and descriptions for the main controller and various communication cables.

Power Transformer Specification

Information regarding the MTS power transformer, including input and output specifications.

Power Head Exploded View

Power Head Component Diagram

An illustrated exploded view showing all components of the power head assembly.

Power Head Parts Identification

95 MTS Powerhead Part Numbers

Comprehensive list of part numbers and descriptions for the 95MTS powerhead.

Additional Components List

List of system components not shown in the exploded view, including controllers and valves.

Valve Body Exploded View

Valve Body Component Diagram

An illustrated exploded view detailing the components of the valve body.

Valve Body Parts Identification

95 STS;MTS Valve Body Parts List

Detailed list of part numbers and descriptions for the 95STS/MTS valve body.

Valve Body Parts Identification (Continued)

DLFC, Connector, and Injector Options

Lists various part numbers for DLFCs, connectors, and injector throat/nozzle options.

BLFC Options and Tubing Connectors

Part numbers for BLFC options and connectors for tubing to the brine line.

Troubleshooting Common Issues

Regeneration Initiation Failures

Diagnosing and resolving problems preventing the unit from starting a regeneration cycle.

Hard Water and Salt Usage Problems

Troubleshooting steps for hard water issues and high salt consumption.

Water Pressure and Brine Line Issues

Addressing low water pressure, resin in drain line, and brine draw problems.

Valve Cycling and Beeping Sound Issues

Troubleshooting continuous valve cycling and unexpected beeping sounds.

Maintenance Logs and Records

Annual Maintenance Log

A log sheet for recording yearly maintenance tasks performed on the system.

Maintenance Logs and Records (Continued)

Monthly Maintenance Log

A log sheet for recording monthly maintenance checks and observations.

Maintenance Logs and Records (Continued)

Weekly Maintenance Log

A log sheet for recording weekly maintenance activities and regeneration counts.

Maintenance Logs and Records (Continued)

Daily Maintenance Log

A log sheet for recording daily checks on brine tank, water hardness, and alarms.

Maintenance Logs and Records (Continued)

Brine Tank Salt Addition Records

A log to track the number of regenerations and weight of salt added to each brine tank.

Commercial Softener & Filter Unit Warranty

Warranty Coverage Table

Details the warranty periods for various components of the assembled unit.

Warranty Limitations and Exclusions

Outlines conditions that may void the warranty, such as misuse or improper installation.

Canature WaterGroup 95MTS Specifications

General IconGeneral
BrandCanature WaterGroup
Model95MTS
CategoryWater Dispenser
LanguageEnglish

Related product manuals