1. This manual contains important safety and operating instructions. Read all instructions and follow
them when using this product. Failure to consider this information and follow these instructions,
including those concerning maintenance, may result in property damage, injury and or death.
Page 27 of this manual contains important maintenance procedures for the continued proper
operation of your unit. These MUST be performed regularly for your warranty to remain valid.
2. We recommend installation only be completed by a competent installer or plumbing professional to insure this
product is installed in accordance with local plumbing codes.
3. Read this manual in full and follow all instructions carefully before operation.
4. Avoid pinched O-rings during installation by applying NSF certied lubricant to all seals (provided with install kit).
5. This system is not intended for treating water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
6. Discard small parts remaining after the installation.
7. Failure to install the system correctly voids the warranty.
8. Handle all components of the system with care. Do not drop, drag or turn components upside down.
9. Save these instructions and keep track of your product’s serial number.
NOTICE: THIS MANUAL CONTAINS A LIMITED WARRANTY. BY INSTALLING AND OR USING THIS PRODUCT, YOU WAIVE
CERTAIN LEGAL RIGHTS INCLUDING THE RIGHT TO SUE OR CLAIM COMPENSATION IN THE EVENT OF PROPERTY
DAMAGE, INJURY, AND OR DEATH.
Canature WaterGroup Canada Inc.
855 Park St., Unit 1
Regina, SK, S4N 6M1
Toll Free: (877) 288-9888
Canature WaterGroup U.S.A. Inc.
6353 Commerce Drive
Whitestown, IN, 46075
Toll Free: (877) 288-9888

Questions and Answers

  • R
    Robert ArellanoAug 18, 2025
    Why does my Canature WaterGroup Water Filtration System bleed taste and odor?
    • D
      devon15Aug 19, 2025
      Taste and odor issues with your Canature WaterGroup Water Filtration System can arise from several causes. First, ensure the bypass valve is closed. Check that the unit has continuous electrical service by inspecting the fuse, plug, or switch. The media bed might be defective or stripped, requiring replacement. A change in water quality may necessitate a water sample analysis. The filter capacity could be too small, suggesting a replacement with a larger unit or adding another filter. Insufficient backwashing, possibly due to a clogged flow control, restricted drain line, or inadequate water pressure, can also be a cause. For calendar clock models, excessive water usage might be the issue; increase the regeneration frequency and check for leaks in toilets or sinks.
  • R
    Ruben ValdezAug 21, 2025
    What to do if I have loss of water pressure with Canature WaterGroup Water Filtration Systems?
    • L
      lcobbAug 21, 2025
      A loss of water pressure in your Canature WaterGroup Water Filtration System could be due to a few reasons. Iron or turbidity might have built up in the filter; in this case, clean the control, treat the bed with Iron Out, and increase the regeneration frequency. Also, the filter might not be regenerating often enough, so try increasing the regeneration frequency. Finally, there might not be enough water volume or pressure to backwash properly, so you should correct the water supply problem.
  • J
    Jennifer JacksonAug 23, 2025
    How to fix a Canature WaterGroup Water Filtration System that fails to regenerate?
    • C
      Christopher KimAug 23, 2025
      If your Canature WaterGroup Water Filtration System isn't regenerating, start by ensuring it has continuous electrical service by checking the fuse, plug, or switch. If the power supply is consistent, the timer might be defective and need replacement. In case of a power failure, reset the time of day. Lastly, the timer motor itself could be faulty, requiring replacement.
  • A
    andrea55Aug 26, 2025
    What to do if Canature WaterGroup Water Filtration Systems drain flows continuously?
    • R
      Robert ChandlerAug 26, 2025
      If the drain is flowing continuously in your Canature WaterGroup Water Filtration System, it could be due to foreign material in the control. Remove the piston assembly, inspect the bore, remove any foreign material, and check the control in various regeneration positions. Alternatively, the timer motor might be stopped or jammed, requiring replacement.
  • S
    Stephanie FritzAug 28, 2025
    Why is media lost through the drain line in Canature WaterGroup Water Filtration Systems?
    • A
      Anthony McguireAug 28, 2025
      Losing media through the drain line in your Canature WaterGroup Water Filtration System can occur if there's air in the water system. Ensure your well system has a proper air eliminator control and check for a dry well condition. Another cause could be that the backwash rate is too fast. Check the drain flow control for proper flow rates.
  • T
    Tiffany RodriguezAug 30, 2025
    Why does my Canature WaterGroup Water Filtration System regenerate every day?
    • S
      Savannah BestAug 30, 2025
      If your Canature WaterGroup Water Filtration System is regenerating every day, the issue might be a faulty gear train. Check the mechanical linkage on the timer control to eliminate possible binding in the gear train.
  • M
    melissagonzalezSep 1, 2025
    Why is my Canature WaterGroup 85DF Water Dispenser delivering untreated water?
    • T
      Thomas McclainSep 1, 2025
      Your Canature WaterGroup Water Dispenser might be delivering untreated water due to several reasons: * The bypass might be closed, preventing water from being treated. Return the bypass valve to the open position. * There might be a bypass loop in your home's plumbing. Close the outlet valve on the softener bypass and open the nearest softened water line. If water flows, there's a hidden bypass, and you should contact the installer. * The salt level might be too low. Add salt above the water line in the salt tank, as low salt levels can affect the softener's capacity. * The unit might not be programmed correctly for your application. Verify that the programming is set correctly for your water hardness level and the number of people in your home.
  • C
    Charles BrownSep 3, 2025
    What to do if my Canature WaterGroup 85DF Water Dispenser is using more salt than expected?
    • L
      Lisa TuckerSep 4, 2025
      If your Canature WaterGroup Water Dispenser is using more salt than expected, check the programming to ensure it is correct for your water hardness and the number of people in your household. Also, verify that the unit is set properly for salt efficiency.
  • J
    James PearsonSep 6, 2025
    What to do if my Canature WaterGroup 85DF has alarms after regeneration?
    • M
      myerscarlosSep 6, 2025
      Alarms after regeneration in your Canature WaterGroup Water Dispenser can be caused by a power outage or brownout during regeneration. Try unplugging the power for thirty seconds and then reconnecting it. If the alarm continues, it may be caused by a corroded or damaged rear circuit.
  • A
    Alicia BergerSep 8, 2025
    What to do if my Canature WaterGroup Water Dispenser is delivering discolored water?
    • Y
      ypayneSep 8, 2025
      If your Canature WaterGroup Water Dispenser is delivering discolored water, first check with your local water authority to see if there has been water main activity in your area. If so, manually regenerate the unit a couple of times to clear the color. Discolored water can also be caused by iron bleed through. See settings to compensate for iron in the water.

Canature WaterGroup 85DF Specifications