We subscribe to the recommendations for the number and placement of smoke and/or heat detectors found in the
National Fire Protection Association's Standard #72, Chapter 2 (N.F.P.A. Batterymarch Park, Quincy, MA 02269).
For the best early warning, fire detection devices should be installed in all rooms and areas of the premises. A smoke
detector should be installed in each separate sleeping area, in the vicinity of bedrooms. (In new construction, a smoke
detector shall be installed in each separate sleeping room.) Heat or smoke detectors should be installed in living rooms,
closets, utility and storage rooms, basements, and attached garages.
BED-
ROOM
Place detectors near
top of stairwells
BED-
ROOM
BED-
ROOM
DINING
ROOM
KITCHEN
FAMILY
ROOM
BED-
ROOM
LIVING ROOM
Place detector near all sleeping areas
BED-
ROOM
BEDROOM
BASEMENT
K
S
C = CONTROL
= SMOKE DETECTOR
= SOUNDER
= KEYPAD
BEDROOM BEDROOM KITCHEN DINING
ROOM
BEDROOM LIVING ROOM
Best residential detector placement between
bedrooms and the rest of the house