TECHNICAL DATA
DIMENSIONS
Height 900 - 915mm
Width 600mm
Depth 595mm (excluding door handles)
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
ā€ BSP female)
Supply pressure G20 at 20 mbar
Pressure test point Grill injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.
Main Oven Heat Input 2.5kW
INSTALLATION INSTRUCTIONS
HEAT INPUT
BURNER
3.7 kWGRILL
2.0 kWTOP OVEN
3.0 kWHOTPLATE
Front left and rear right
1.8 kWHOTPLATE
Front right and rear left
INJECTOR
150
100
134
109
29