ir33 Universale
User manual
electronic controller
Question and Answer IconNeed help?

Do you have a question about the Carel IROPZKEY00 and is the answer not in the manual?

Carel IROPZKEY00 Specifications

General IconGeneral
BrandCarel
ModelIROPZKEY00
CategoryController
LanguageEnglish

Summary

Introduction to CAREL IR33/DN33 Controllers

Controller Functions and Features

Details the operating modes, special modes, and available accessories for the controllers.

Controller Installation and Setup

Programming Key Setup

Explains how to use the programming key to transfer settings.

User Interface and Programming

Parameter Programming

Details how to set frequent (P) and configuration (C/d) parameters.

Commissioning and Configuration

Configuration Settings

Sets serial address, enables interfaces, and configures start-up delays.

Controller Functions and Operating Modes

Probe Configuration

Parameters for setting probe type, calibration, and filters.

Standard Operating Modes Overview

Describes direct, reverse, PWM, and alarm operating modes.

Special Operating Mode Configuration

Selecting Special Operating Mode

Enables custom operating logic and special parameters via c33.

Special Parameters for Output Configuration

Defines parameters for individual output configuration (dependence, type, activation, etc.).

Output and Input Operations

Control Strategies

ON/OFF and PID Control Comparison

Compares ON/OFF control with PID control for systems.

Setting Control Type

Sets the control type (ON/OFF or PID) using parameter c5.

PID Tuning Parameters

PID parameters for integral and derivative time settings (c62,c63).

Auto-Tuning Procedure

Procedure for automatically tuning PID parameters using c64.

Advanced Control Operations

Auto-Tuning During Commissioning

Details Auto-Tuning procedure during system setup.

Probe 2 Operations and Compensation

Differential Operation with Probe 2

Control based on the difference between two probes (c19=1).

Compensation in Cooling

Modifies set point based on outside temp. in cooling (c19=2).

Compensation in Heating

Modifies set point based on outside temp. in heating (c19=3).

Special Operation Logic and Compensation

Parameter Reference Tables

Control Parameter Definitions

Lists parameters for set points, operating modes, and control differentials.

Output and Alarm Parameter Definitions

Lists parameters for output control, alarms, and digital inputs.

Advanced Function Parameter Definitions

Lists parameters for software revisions, timing, and alarms.

Alarm Management

Comprehensive Alarm Table

Table of alarm codes, messages, and control actions.

Alarm Parameter Configuration

Technical Specifications and Product Information

Related product manuals