Mechanical installation
WTS LARGE +0300131IT rel. 1.0 - 05.09.2022
5.2 Installation steps
5.2.1 Feed water connection
» Install a shut-off valve
» Connect the feed water inlet to the system. The diameter of the raw water pipe must be at least equal to the
diameter of the connection piece.
» Observe the information in the technical data.
ROL-160/-320 ROL-460 - 1200
5.2.2 Permeate pipe connection
» The diameter of the permeate pipe must be at least equal to the diame- ter of the connection piece.
» Connect the permeate pipe to the corresponding connection piece and then connect the pipe (not included
in the delivery) to the expansion tank or return pump tank.
» Note the information in the technical data.
ROL-160/-320 ROL-460 - 1200
Notice: Do never operate the unit with the permeate line closed!
5.2.3 Connection of the expansion vessel
» Mount the holder* of the expansion tank on a stable wall or ensure a secure stand on the floor.
» If necessary, connect the connection set to the expansion vessel.
» Install shut-off valves as shown in the following figure