26
ENG
WTS LARGE +0300131IT rel. 1.0 - 05.09.2022
Electrical connection
7.5 Inputs and outputs of the main board
Clamp Describtion WL-ROL
1[L] - 2[earth] - 3[N] 230-V 50/60 Hz-Input for system power supply
ü
4[L] - 5[earth] - 6[N] 230-V-Output for pump supply
ü
7[L] - 8[earth] - 9[N] 230-V-Output for dosing pump
ü
10[L] - 11[earth] - 12[N] 230-V-Output for inlet valve
ü
13[L] - 14[earth] - 15[N] 230-V-Output for ush valve
ü
19[NO] - 20[C] - 21[NC] alarm aoutput optional
ü
22[C] - 23[IN] input pressure switch Feed water connection / Max pressure
ü
24[C] - 25[IN] input high pressure switch pump pressure
ü
26[C] - 27[IN] input pump motor protection X
28[C] - 29[IN] input alarm dosing pump
ü
30[schielded] - 31 - 32 conductivity sensor feed water
ü
33[C] - 34[IN] input pressure switch Feed water connection / Min pressure
ü
35[C] - 36[IN] input low pressure switch
ü
37[C] - 38[IN] input Remote-On/O optional
ü
39[C] - 40[IN] input softening lter
ü
41[shielded] - 42 - 43 conductivity sensor row water
ü
7.6 Technical sheet: Booster pump (RTM300M2000)
Description DATA
Tank material PE
Volume 300 l
Diameter 630mm
Height 1300mm
Width 880mm
Depth 760mm
Voltage 220V
Frequency 50Hz
Power 0.91kW
Inlet (from osmosi) G ¾’ Male
Overll G 1’ Male
Outlet (from pump) G 1’ Male
Drain tank G ¾’ Male
Fig. 7.b
Fig. 7.c
Overfill: connect to
a free drain, G 1" M
Water inlet: connect
to the WTS, G 3/4" M
Floating connector:
connect to the WTS
controller
Water outlet: connect
to the users, G1" F
Power connect to
single-phase
220 V - 50 hz
Tank drain: connect
to a free drain,
G 3/4" F