EasyManuals Logo

Carel pGDx Touch 4.3” User Manual

Carel pGDx Touch 4.3”
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
+05C001895 - rel. 1.2 - 02.04.2019
䇤⿈㬷⤺㡘pGDx Touch 4.3” -
User terminal pGD Touch 4.3”
pGDx
⨀⫈ (mm) / Dimensions (mm)
151,5
87,7
8,9
133,8
125,7
67,5
33,1
43,9
116,6
84,3
133,8
42
31,6
4
RIGHT
WRONG
134
Ø 4
34.5
dima di foratura
drilling template
127x69 mm
㣞㘇➓䓑㞅ミ (㧈㵝3d) - ⥛㠘⫛㕌󰵼 PGTA00SM40
Accessory for wall surface installation (ref. Figure 3d) - P/N: PGTA00SM40
31,9
151,7
133,8
87,8
23
57,3
83,5
57,3
83,5
41,9
45,9
RIGHT side connection CHI/DE STANDARD
RIGHT side connection STANDARD 503
LEFT side connection (Ethernet version) STANDARD 503
LEFT side connection CHI/DE STANDARD
㣗㧌㬞➓䓑㞅ミ (㧈㵝3c) - ⥛㠘⫛㕌󰵼 PGTA00RM40
Accessory for ush-mounted wall installation (ref. Figure 3c) - P/N: PGTA00RM40
63,1
54,2
150,8
86,9
133,8
148,3
82,8
to remove for plasterboard installation
to remove for plasterboard installation
Fig. 1
䔊䓑⼮➓䓑 (mm) /
Assembly and installation (mm)
䎞㘇 / Frontal
127 mm
Ø 4
134 mm
34,5 mm
69 mm
Fig.3a
⡔㘇 / Back
118 mm
40
134 mm
86 mm
5
5
34,5 mm
86 mm
5
5
policarbonate
Fig.3b
㣞㘇➓䓑Wall mounting
Fig.3c
㣞㘇 Wall surface
Fig.3d
Introduction
The pGDx 4.3 inch graphic terminal is part of the family of touchscreen terminals designed
to simplify user interface with the pCO sistema family controllers. The electronic technology
used and the new 65K colour display means high quality images and advanced functions
are available for a superior appearance. The touchscreen panel moreover makes interaction
between the user and the unit much easier by simplifying navigation between the various
screens. Dierent types of installation are available, depending on the model: front or
back panel, wall surface or ush-mount. In any case, the device can be mounted either
horizontally or vertically.
Part numbers
Codice
No. RS485
ports
No. ETH
ports
Wi-Fi
connectivity
No. RJ12
ports
Power supply
port
PGR04****A*** - - - 1 -
PGR04****B*** 1 - - - 1
PGR04****C*** 1 1 - - 1
PGR04****R*** 1 1
9
- 1
PGR04****W*** 1 -
9
- 1
PG[B,R]04****E*** - 1 - - 1
PG[B,R]04****H*** - 1
9
- 1
Packaging contents
pGDx; power supply and RS485 connectors (only on models where featured); fastening
screws; technical leaet, Wi-Fi antenna (only for models where tted, PG*04***D[H,R,W]***).
Not included: frame, PGTA00TRX0 power supply and wall mounting boxes
.
Installation warnings
For correct installation contact a qualied installer.
Do not install the terminals in environments with the following characteristics:
relative humidity greater than the value specied in the technical specications;
strong vibrations or knocks;
exposure to aggressive and polluting atmospheres (e.g.: sulphur and ammonia fumes,
salt spray, smoke) so as to avoid corrosion and/or oxidation;
strong magnetic and/or radio frequency interference (therefore avoid installing the units
near transmitting antennae);
exposure to direct sunlight or the elements in general;
large and rapid uctuations in the room temperature;
environments where explosives or mixes of ammable gases are present.
The following requirements shall be met:
with built-in temperature/humidity sensor, it is recommended to:
only use faceplates tted ventilation openings
install the display away from air streams coming from heating/cooling systems
if installed vertically, position the probe at the bottom of the display
only use shielded cables for Ethernet and RS485 communication networks;
power supply voltages other than those specied may seriously damage the system;
use cable ends suitable for the corresponding terminals. Loosen each screw and insert the
cable ends, then tighten the screws. When the operation is completed, slightly tug the cables
to check they are suciently tight;
in models with an external WiFi antenna, ensure at least basic insulation (500 Vac
according to IEC 60730-1) between the RP-SMA connector and the protective earth;
do not open the product when powered;
operation at low temperatures may cause a noticeable decline in the response speed of the
display. This should be considered normal and does not indicate a malfunction.
for one correct installation of IP65 models be safe of a 0,4 Nm screws tightening and a
correct assembly of the gasket.
avoid any contact of the product with live parts.
be sure that cables are accurately xed in order to avoid contact with live parts in case of
their accidentally disconnection.
Meaning of the colours on the notification bar
At power-on, the notication bar briey shows a blue signal to indicate the start of the
boot phase. The subsequent signals are then managed by the application program
developed using c.touch.
HMI Runtime and/or application update
1. Copy the update package (.ZIP le) containing the runtime
or application, or both, depending on the options selected
when generating the “Update package” using c.touch, to a
USB pendrive and then plug the pendrive into the pGDx and
hold the pGDx terminal screen for a few seconds until the
shortcut menu is displayed, disableable application side (see
the gure on the side):
2. Select “Update… to
start the Runtime and/
or application update
procedure. The update
utility will start and the
following window will
be displayed:
3. Then follow the
guided procedure,
selecting the le
saved on the USB
pen drive and
clicking the next
button to conrm.
System settings
Touch and hold the pGDx terminal screen
for a few seconds until the shortcut
menu is displayed (see the gure below).
Select “Show system settings”; the main
conguration program screen will be
displayed (gure on the side):
Below is a list of the functions relating to the dierent menu items:
Language Set the system language (not the c.touch application)
System
Contains information on the pGDx: BSP version, Memory, Timers
and temperature / humidity sensor (if featured)
Logs Download the system log les
Date & Time Set pGDx date and time using the automatic or manual procedure
Network
Show current system IP data (address, subnet, Gateway, DHCP, DNS)
and access the Ethernet and WiFi interface
Services
Start/stop various system services (Modbus server port, pGDx
network address,…)
Management
Update the dierent pGDx BSP partitions (CongOS, MainOS,
Bootloader, Splash image, etc.…)
Display
Set brightness, backlight timeout, screen orientation and touch
panel calibration
Restart Restart the system
Authentication Set the password used to access
EXIT Exit the menu
⢃㠞㼀㎣⪊⺞
(㆗㬫䇤䇻⤪䇤㶃
䐤ポ㝭)
Flat cable passage
(only in case
of external keypad)
㶃㌓⥛㠘⫛㕌
Frame code:
PGTA**F[T,H][0,1]*
㶃㌓⥛㠘⫛㕌
Frame code:
PGTA**F[T,H][0,1]*
⡙䓃󰵼
㤌㹑ㅌ⮈䊕㼀
⪊⺞㣗㧌㬞➓
䓑⼱
Note:
Do not run power
cables inside the
ush-mount box
䐹䄋㳂㬟󰵼
㤌ㅌ⢃㠞㼀㎣䈌
㆑㭕㘇⟆⳷㋋
Important:
keep the at cable
isolated from the
metal panel
⡙䓃󰵼
㆗㬫䇤䇻㾮⼦
PG*******[B,E,W,H]***
Note:
can only be used
with models
PG*******[B,E,W,H]***
㶃㌓⥛㠘⫛㕌
Frame code:
PGTA**F[B,W][0,1]*
Carel㳂⹊
Not supplied by Carel
➖㼀㼅 / Wall box
standard ITA/CHN/DEU/USA
䅃⫔㏜䐱⺛⭣⺛㗡
⺛⢋䓝
㆕⹭㝅㑇 0.4 Nm
Tightening torque 0.4 Nm
⥛㠘ㆊ㩽
pGDx 4.3⫈㵝㾯䐶Ⱜ㬨⪆㘟㬞㻵㬟㠢⥛㠘㻖㑱䐱⭥䄜⤠⳷󰵮䓉㸋ビ⿐䈌pCO sistema
㻖㑱㋹䐧㡘⭥ⰵㅴⱙ㪉ェ᱄⪬㵝㾯䐶Ⱜ⤪䇤⭥⮈䓴ゝ㭖ゑ㾣㾮⭥65K㩌⤫㻵㬟󰵮㋪
㳂⹊ⷀ㠘䐫㵝㼒⼮㻩㆙⭥⹇㚽󰵮㵝㾯ㆈ㘇ⷝゴ⨗䐻᱄⪆㘟㬞㘇⟆ビ⿐㑬⤜㵍ㆈ㘇䐏
ヅ⭥⭝⼞󰵮㬚䇤⿈⼮〛䔊䐏ヅ⭥⿆Ⱀⷝゴビ⭆᱄䇱ⱁ䐷➓䓑㏁㾮⭥⤜㵍⥛㠘㋪㳂
⹊󰵼䎞㘇〓⡔⟆᱃㣞㘇➓䓑〓㣗㧌㬞➓䓑᱄⭌⤜⹽⤪䇤㚥䐷㾮⼦󰵮⪬䐶Ⱜ㉚㋪䄵㯏
㠞➓䓑〓⪚䐒➓䓑᱄
⥛㠘⫛㕌
⫛㕌
RS485Ⱜ㋻
㭞㑠
ETHⰬ㋻
㭞㑠
Wi-Fi㑍ㅴ
RJ12 Ⱜ㋻
㭞㑠
⮈䊕㋻
PGR04****A*** - - - 1 -
PGR04****B*** 1 - - - 1
PGR04****C*** 1 1 - - 1
PGR04****R*** 1 1
9
- 1
PGR04****W*** 1 -
9
- 1
PG[B,R]04****E*** - 1 - - 1
PG[B,R]04****H*** - 1
9
- 1
⟝䓑㘘㻙
pGDx䐶Ⱜ󰵮⮈䊕⼮RS485㑍ㅴ㵘㆗㬫䇤⫙⪬ㅴ㵘⭥㾮⼦󰵽㆕⹭㔾㯠󰵽ゝ㭖㸥
⭖󰵮Wi-Fi㳍㼀㆗㬫䇤⫙⪬ㅴ㵘⭥㾮⼦PG*04***D[H,R,W]***᱄⤜⟝㎉󰵼㯽㑰㶃
㌓󰵮PGTA00TRX0⮈䊕⼮➖㼀⼱᱄
➓䓑䓃䅃㬣㼏
㸋㦘⡄➓䓑䎞㦘󰵮㤌㑋㕈䇱䓫䐫⭥➓䓑⹅᱄
㤌㹑ㅌ䐶Ⱜ➓䓑䊻㉀䇱㻣㑱㲹⮄⭥⿘㈔䐱󰵼
 㼁ⰵ㬋Ⱙⷀ䇻ゝ㭖⺇ⷒ䐱⺇Ⰹ⭥䐖󰵽
 ㉀䇱㣠㑳䎑Ⱀ〓⨆〘󰵽
 ⡊㔗䇻㣷㬕⼮㸼㦟䐱⭥⿘㈔㏞㧈󰵼㒓⼮➒⭥㡙㳆᱃䁯㹎᱃䁭㹎󰵮䄵ⳡ䐚ⶐ㬕
⼮〓䂖⿐󰵽
 ⫇䊻㣠㑳⪦㾵⼮〓㸿㼀⮈㠖㔫ⶪ㦦⭥⿘㈔䅓⪬㣱㹑➓䓑䊻ⳃ㪅㳍㼀⶞㆝󰵽
 ⡊㔗䊻䂕⺃䐒㪅⭥⿘㈔䐱᱄
 Ⳡヅ㸣Ⱙ⤉Ⱀ⫔㣳を㯺󰵽
 ⫇䊻⡍䍉㹐〓㋪㦝㡙㳆」⼰㹐᱄
䄵㻣䄋㤔⡹㿌㕛䔄󰵼
 㧈⺜㚻䐤㸣Ⱙ㬋Ⱙ⪌ⶱ㡘󰵮ㅉ䅊󰵼
䐜㬚䇤㞅䐤㵉ⴈ㋻⭥㘇⟆
ㅌ㻵㬟㠢➓䓑䊻䊗㏌䐧㏅䐧㦩㻖㵔㡙㒘㶃
㧈⺜㬨⪚䐒➓䓑󰵮㤌ㅌ⪌ⶱ㡘Ⰹ㸜䊻㻵㬟㠢㻣Ⳟ
 ㆗㬚䇤㠢⡯㼀󰵮䇤䇻EthernetRS485㵉䁗㶙㕈󰵽
 㧈㬚䇤⢋Ⰹ䄵㶃⭥⮈䁚㋪㚽。䁰䐹㰑⿖㻖㵔󰵽
 㬚䇤㬫⼰䇻㼁䇇䐶Ⱜ⭥㼀㎣㵘᱄㯪㋋㗠⷗㔾㯠⤃⥆㧌㼀㎣㵘󰵮㦜⽔㆕⹭㔾㯠᱄⤺
䔘㶋⧪⽔󰵮㤂㤂㎎Ⱀ㼀㎣󰵮ネ⥊㼀㎣㬨ⴒ䄲⹭Ⰹ⼤󰵽
 㧈⪆㘟㠢㬚䇤㶃䐤WiFi㳍㼀󰵮㦘⡄䐢㩺〚⡟⭥ⷕ㏌ (500 Vac󰵮ⷚ㈾IEC 60730-1)
RP-SMAㅴ㵘⼮⡄⿅ㅴ⭹䐏ヅ󰵽
 㤌㹑䊻㩰⮈㬒⫓㋋⡟䐶Ⱜ󰵽
 ⭮㸣䊬㾱㋪㚽⭝䐣㻵㬟㠢ⳕ䇇㯺Ⱙ⭥㻵䑙㻣ㅖ᱄⪬䐷㻷㼔⡜㬴㸋䎞⧄㻷㼔󰵮ⱙ⤜
。⢋㬗㸋⹫䍰󰵽
 ⰵ䇻ⳡ⿅⭩゗㸋IP65⭥㾮⼦󰵮䎞㦘➓䓑Ⳟ㬞㸋㔾㯠㆕⹭㝅㑇㸋04 Nm󰵽
 ⡽㘃ㅴ⪆䐶Ⱜ㩰㦯⼯⫙⮈⭥⤠ミ󰵽
 㦘⡄㼀㎣⹭Ⰹ䓝㦘󰵮⡽㘃ㅴ⪆⫙⮈⤠ミ󰵮䄵ⳡ䐶Ⱜⳃ㪛䅃㶃ⰰ㋋᱄
㵉䐋㎙㩰⭥䁶㩌⼍䅆
㩰⮈㬒󰵮㵉䐋㎙Ⱝ㬒㻵㬟䄜⷗㎗㩌㾦⼦󰵮⢎㬟bootㅸⰯ㡕Ⱀ᱄㰇⽔⭥㾦⼦ㅌ䇪
c.touch㋋ⳃ⭥䇇䇤⧭㿓㆙㾱⹽㏎᱄
HMI䊬㾱㬒ヅ⼮〓⧭㿓ⷝ㾣
 ⷚ㈾䇤c.touch㪛⧪“Update package” )ⷝ㾣⟝㬒䁂䋒⭥
䁂㼏󰵮ㅌ⟝⼍䊬㾱㬒ヅ〓⧭㿓〓㑞⷗Ⱍ䇱⭥⭥ⷝ㾣⟝
(.ZIP le)󰵮ⶕ䐧⭞䄜⷗USB㤞Ⱀ㡘󰵮㦜⽔䊺ㅌUSB㤞Ⱀ㡘
⥆⭞pGDx󰵮➕䓂pGDx䐶Ⱜ㻵㬟㠢⧷㿙゙㘌䐴󰵮䐒⭞㻵
㬟㌍ㅾ⤬⭆󰵮㋪㬚⧭㿓⥁㬈㾈⤯㋝䇳⥁㵝󰵼
 䁂䋒“Update…”)ⷝ㾣
䊬㾱㬒ヅ⼮〓⧭㿓
ⷝ㾣᱄㡕Ⱀⷝ㾣󰵮㦜
⽔ㅌ㻵㬟㻣㘇䎃⷗
⪑㋻󰵼
 㦜⽔➕䍶䅞⭝⭥
⤞䑉󰵮䁂䋒⡄⫇
USB㤞Ⱀ㡘㩰
⭥㸥ミ󰵮⤃㣳⮄
〘㻣䄜⷗➕㝆䄵
㦘㦰᱄
㻖㵔㪉Ⰹ
⪆Ⱀ⤃➕䓂pGDx䐶Ⱜㆈ㘇⧷㿙゙㘌
䐴󰵮䐒⭞㻵㬟㌍ㅾ⤬⭆㧈㻣㵝󰵮
䁂䋒㻵㬟㻖㵔㪉Ⰹ“Show system
settings”󰵽䑘䄋㞅䐤⧭㿓ㆈ㘇ㅌ㻵㬟
㧈⥁㘇㵝󰵼
㻣⢎㸋䈌⤜㵍⤬⭆㼏㚠䇱⹹⭥⹇㚽㤆⭆󰵼
䈐䁵
㪉Ⰹ㻖㵔䈐䁵⳨c.touch⧭㿓
㻖㵔
⟝⼍䊻pGDx㩰⭥㾦㻃󰵼BSP⟇⡟󰵮⫇⪃㡘󰵮Ⰹ㬒㡘⼮㸣Ⱙ㬋
Ⱙ⪌ⶱ㡘㧈⺜䄲㞅䐤
㦶䐟 㻣䊹㻖㵔㦶䐟㸥ミ
㦶㠻㬒ヅ
㬚䇤䓵Ⱀ〓㬷Ⱀ⤞䑉㪉ⰉpGDx⭥㦶㠻⼮㬒ヅ
㶙㕈
㻵㬟⭒㣑㻖㵔IP㭞㈾(⭹䐘᱃䓴㶙㕈᱃㶙⹹᱃DHCPDNS)⤃ⳤ
㸫䄵㲌㶙⼮WiFiㆈ㘇
ⴟ㹒
㡕Ⱀ㵄䐚⤜㵍㻖㵔㪉⡙Modbusⴟ㹒㡘Ⱜ㋻󰵮pGDx㶙㕈⭹
⹽㏎
ⷝ㾣⤜㵍pGDx BSP⳷㤙(CongOS, MainOS, Bootloader󰵮㋋〛㵝
㼒󰵮⭩⭩…)
㻵㬟 㪉Ⰹ㑢Ⱙ󰵮⡔⺃⧍㬒󰵮ㆈ㘇Ⳟ㼓⼮⪆㋹㘇⟆㾄䓝
䐹㡕 䐹㡕㻖㵔
㬻㦉 㪉Ⰹ㗽㕌󰵮䇤䇻ⳤ㸫
㵬⨗ 㵬⨗⤬⭆

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carel pGDx Touch 4.3” and is the answer not in the manual?

Carel pGDx Touch 4.3” Specifications

General IconGeneral
BrandCarel
ModelpGDx Touch 4.3”
CategoryTouch terminals
LanguageEnglish

Related product manuals