10
Downcalls Internalstatus Is1ifthereisanydownlanding
call
Fullload Internalstatus Is1iftheoverloadsensor
indicatesfullload
Overload Internalstatus Is1iftheoverloadsensor
indicatesoverload
Blockeddoors Internalstatus Is1ifthedoorsareblocked
UPS Internalstatus Is1iftheUPSsignalisactivated
Invertererror Internalstatus Is1iftheinvertererrorsignalis
activated
PTCerror Internalstatus Is1ifthereisanerrorwiththe
PTC
Tempsensorerror Internalstatus Is1ifthemachineroom
temperatureisbeloworaboveof
theallowedone
Firealarm Internalstatus Is1isthefiresignalisactivated
microSDpresent Internalstatus Is1ifthemicroSDcardis
pluggedin
Handheldconsolepresent Internalstatus Is1ifthehandheldconsoleis
connectedonthecontroller
Carlight Internalstatus Is1whenthecarlightisatON
state
Fl0,Fl1,Fl2,Fl3,Fl4,Fl5,Fl6,
Fl7,Fl8,Fl9,Fl10,Fl11,Fl12,
Fl13,Fl14,Fl15,Fl16,Fl17,Fl18,
Fl19,Fl20,Fl21,Fl22,Fl23
Internalstatus Is1whenthecarisonthatfloor.
Example:
Ifisprogrammedas“Fl4”this
inputwillbe1
whenthecarison
floor4
Sun,Mon,Tue,Wed,Thu,Fri,Sat Internalstatus Is1whenisthisweekdayonthe
internalrealtimeclockofthe
controller
Example:
Ifaninputisprogrammedas
“Sat”willbe1from0:00:00until
23:59:59ofeachSaturday
0h,lh,2h,3h,4h,5h,6h,7h,
8h,9h,10h,11h,12h,13h,14h,15h,
16h,17h,18h,19h,20h,21h,22h,23h
Internalstatus Is1whenisthathouronthe
internalrealtimeclockofthe
controller
Example:
Ifaninputsisprogrammedas
“13
h”willbe1from13:00:00until
13:59:59everyday