EasyManuals Logo

Carlos Silva HIDRA CRONO User Manual

Default Icon
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
Introduction
From firmware version 5.0, The Hidra Crono controller has an optional PLC feature (Programmable
logiccontroller)toallowtheimplementationofspecialfunctionsinafastandeasyway.
Withthisnewfunctionalityitis possibletoprovide theliftofpracticallyanyspecificfunctionofthe
buildingwithoutthe
needtoaddexternalelements,spendtimeaddingadditionalwiringorexternal
elementsofcontrol
Thissoftwaremoduleisdesignedtonotaffectthenormaloperationofthelift.Becauseofthis,itis
not possible to change specific functions of this. Below are indicated some examples of the
possibilitiesoffered
bythePLCmodule.
Glossary
Inthisma nualtherearesomereferencesatsomeconceptsthatisnecessarytobe clearinorderto
understandcompletelytheoperationofthePLCsoftwaremodule
Inputs
Theinputsmaybephysicalinputs,liftstatus,temporalregistersorpermanentregisters.
ThephysicalinputsarelocatedinanyofthegeneralpurposeinputsoftheHidraCronocontroller(6
oncontroller, 6oncartop,2oneachlandingmodule,8onthepitmoduleand64
onMEXexpansion
modules). A free potential contact is required for this type of inputs, for example key switches,
pushbuttonsorrelaycontacts.
TheLiftstatusinputsaregeneratedbyHidra Cronocontrollerdependingofitsstatus,forexample,if
isdefinedaninputof“inspection” thevalueofthisinput
willbe1whiletheliftisunderinspection.
AnInputoftemporalregisterisaninternalmemorypositionusedtonestvariouselements.Thistype
ofregistersdoesnotmaintaintheirvaluesafterapowerfail.Anexampleoftheuseofthisregisters
isgivenbelow.
Aninput
ofpermanentregisterisaninternalmemorypositionasmentionedbeforebut inthiscase,
itsvalueismaintainedduringapowerfail
Outputs
TheOutputsmaybephysicaloutputs,temporalregisters,permanentregistersorliftfunctions
Asinthecaseoftheinputs,thephysicaloutputsarelocatedonanyofthegeneralpurpos eoutputs
oftheHidraCronocontroller(6onthecontroller,6oncartop,2oneachlandingmodule,
8onthe
pitmoduleand64onMEXexpansionmodules)
OnController,cartop,landingmodulesandpitmodulethereare24VDC1Wmaxoutputs
OnMEXexpansion modulesarefreepotentialoutputs(250VAC5Amax)
An output of temporal register is an internal memory position used to nest various elements.
This
type of registers does not maintain their values after a power fail. An example of the use of this
registersisgivenbelow.