IS1393 C PAGE 2 OF 4
Allows the installer to identify the number of uses the
product has experienced per day during the previous
30 day period.
• Press and HOLD button for 10 seconds to
enter Usage Statistics mode.
• Whilst holding the button, the indicator LED will flash
once after 5 seconds, and then flash again at 10
seconds.
• Release the button.
• The indicator LED will activate for 2 seconds to
acknowledge that Statistics Mode has been activated.
• The indicator LED will now flash in a sequence to
indicate the number of uses the unit has experienced
during the previous 30 day period.
0-20 uses per day 1 flash
21-50 uses per day 2 flashes
51-100 uses per day 3 flashes
101-150 uses per day 4 flashes
Greater than 150 uses per day 5 flashes
The controller can perform internal diagnostic checks
of the main system components and display their
current status.
• Press and HOLD button for 15 seconds to enter
Diagnostics mode.
• Whilst holding the button, the indicator LED will flash
once after 5 seconds, then again at 10 seconds and
again at 15 seconds.
• Release the button.
• The indicator LED will activate for 2 seconds to
acknowledge that Diagnostics Mode has been
activated.
• The controller will check, in the following sequence, the
status of these components:
o Solenoid
o Battery
o Sensor
The controller will provide feedback for each
component by flashing the indicator LED in the
following sequence:
1 LONG flash (3 seconds) indicates component is OK.
3 SHORT flashes indicate an FAULT.