IS1393 C PAGE 1 OF 4
Electronic Flush Valve - Series II
User Manual
The Caroma Electronic Flush valve Series II has several modes to allow the installer to configure the device,
as well as monitor its performance and assist in servicing of the product.
Please ensure that the product has been installed according to the supplied Installation Instructions.
Installation must be done in accordance with AS/NZS 3500.2
Note: All changes to the unit’s settings will be retained in the event of a power outage.
Flush Volume Setting
Default: 0.8L per Flush at 300kPa Supply Pressure.
Allow the installer to select the unit’s flush volume.
Press & HOLD Button for 1 second to CYCLE
through the preset volumes, in the following
sequence:
0.8L (Default) 2 Flashes
1.0L 3 Flashes
1.5L 4 Flashes
2.0L 5 Flashes
0.5L 1 Flash
The indicator LED will flash to indicate the selected
Flush Volume.
Inlet Pressure Setting
Default: 300kPa Supply Pressure
This setting will allow the installer to select the current
water supply pressure to the unit. This information is
used by the controller to determine the duration
required to achieve the preset Flush Volume.
Press and HOLD button for 5 seconds to enter
Pressure Setting function.
The indicator LED will activate once for 5 seconds to
acknowledge that the Pressure Setting function has
been selected.
Release the button.
The LED will flash to indicate the current pressure
setting:
300kPa = 1 LONG Flash; 500kPa = 2 SHORT Flashes
Press & HOLD button for 5 seconds to CYCLE
through the two preset pressure settings;
300kPa (DEFAULT) and 500kPa.
Release the button.
The LED will flash to indicate the selected pressure
setting:
300kPa = 1 LONG Flash; 500kPa = 2 SHORT Flashes
Question and Answer IconNeed help?

Do you have a question about the Caroma II Series and is the answer not in the manual?

Caroma II Series Specifications

General IconGeneral
BrandCaroma
ModelII Series
CategoryControl Unit
LanguageEnglish

Summary

Flush Volume Setting

Setting Flush Volume

Allows installer to select flush volume by cycling through presets.

Inlet Pressure Setting

Setting Inlet Pressure

Allows installer to set current water supply pressure for optimal flush.

Usage Statistics Mode

Viewing Usage Statistics

Displays unit usage over the previous 30 days via LED flashes.

Diagnostic Mode

Running System Diagnostics

Performs internal checks on solenoid, battery, and sensor status.

Usage Duration Settings

Configuring Urinal Sensor Duration

Sets sensor detection time (5, 7, or 9 seconds) for flush activation.

Stadium Mode Settings

Enabling/Disabling Stadium Mode

Activates water-saving mode for high-frequency usage environments.

Smart Flush Mode

Configuring Smart Flush Mode

Sets water-saving mode to monitor usage and adapt flush frequency.

Factory Default Settings Reset

Performing Factory Reset

Restores the unit to its original factory preset configurations.

Related product manuals