Version 5: October 2012
2.4 POWER BLACK- OUT
In the event of a black-out with the machine in:
AGITATION
PASTEURISATION (HEATING or PAUSE stage)
the machine will resume operating in the same function where it was when the power went off.
If the machine was in one of the following functions:
STORAGE
PRODUCTION
PASTEURISATION (COOLING stage)
Upon the return of power, the temperature at the time of failure and the duration of the black-out will be
automatically checked and the machine will resume operating in the same function or it will start a new
PASTEURISATION cycle, in accordance with the applicable safety standards.
CAUTION
If the blackout exceeds four hours, in order to avoid health hazards
in the dispensed product, it is necessary to disassemble, wash, rinse and
sanitize the parts, as indicated in Section 4 of this manual.