When battery terminals are reverse connected, the fuse will blow to protect appliances.
Overheat Protection
When the heat sink temperature exceeds 45°C, the inner cooling fan will switch on automatically to cool the inverter.
When the internal temperature exceeds 70°C, the AC output will shut off automatically and the ALARM/WARNING light will turn red. The unit
will be unusable for 15 minutes.
6. TROUBLESHOOTING REFERENCE
Acoustic buzzer alarms
When using the inverter with acoustic devices, some inferior acoustic devices will buzz, as the output wave from the inverter is a modied
sine wave inverter.
TV Interference
You can reduce interference to a minimum by using a lter. On occasions when the interference of weak signals becomes too obvious, you
can try the following:
Place the inverter some distance away from the TV and TV antenna.
Try to change the direction of the TV signal cable and TV antenna to reduce interference to a minimum.
Use a high-quality screen cable antenna.
Problem: No output voltage
POSSIBLE CAUSES SOLUTION
Battery voltage too low Recharge or replace the battery
Overload Reduce the load
Inverter thermal protection Cool the inverter and position it in a well-ventilated area; Reduce the load
Inverter start-up fail Try starting the inverter again
Reverse polarity connection and fuse melted Replace the fuse with a fuse of equivalent value
Problem.· Inverter no response
POSSIBLE CAUSES SOLUTION
Poor contact between battery and inverter Reconnect the battery and inverter
Reverse polarity connection and fuse melted Replace the fuse with a fuse of equivalent value
Problem.· Output voltage low
POSSIBLE CAUSES SOLUTION
Input voltage too low Make sure the input voltage is within the rated range.
Overload Reduce the load
Problem.· Low voltage alarm
POSSIBLE CAUSES SOLUTION
Battery no power Recharge the battery
Battery voltage too low or poor connection Recharge the battery, check terminal connections or clean terminal with a dry cloth
7 SPECIFICATIONS
ITEMS MODEL
0510350 0510351 0510352 0510353 0510354
Continuous power 150W 300W 600W IOOOW 1500W
Surge Power 300W 600W 1200W 2000W 3000W
Dimensions (L x W x H) 120 x 100 x 50 120 x 100 x 50 150 x 100 x 55 210 x 150 x 70 310 x 150 x 70
Packing PCS/CTN 16 16 16 6 4
KGS/CTN 14.8 15.0 19.0 15.4 12.6
MEAS (L x W x H) cm 44 x 38 x 34 44 x 38 x 34 44 x 38 x 34 42 x 34 x 45 44 x 42 x 33
0510350-62i_A5.indd 50510350-62i_A5.indd 5 08-07-2020 08:1008-07-2020 08:10