Carrier 17M User Manual

Carrier 17M
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Carrier 17M and is the answer not in the manual?

Carrier 17M Specifications

General IconGeneral
BrandCarrier
Model17M
CategoryChiller
LanguageEnglish

Summary

A SAFETY GUIDE

General Safety Precautions

Essential safety advice for operating centrifugal liquid chillers, emphasizing judgement and precautions.

Electrical and Mechanical Hazards

Warnings regarding electrical hazards, moving parts, and pressure systems.

Refrigerant Handling and Cylinder Safety

Safe practices for handling, pressurizing, and storing refrigerants.

Operational and Equipment Safety

Cautions on equipment operation, line safety, and welding.

INTRODUCTION

Document Overview and Job Data

Information on instructions, job data, and system knowledge required.

INITIAL PREPARATIONS

General Preparations and Machine Tightness

Preliminary checks including cleaning, dehydration, and leak testing.

Safety Devices and Lubrication Checks

Verifying safety devices and lubricating drive train and compressor systems.

Piping and Wiring Inspection

Procedures for inspecting system piping and field wiring.

Turbine, Water, and Controller Checks

Checks for turbine, water systems, and level controller settings.

Refrigerant Charging and Alignment

Steps for charging refrigerant and performing alignment checks.

Safety Control Settings Verification

Ensuring all safety controls are properly set and functional.

Load Limiting Control Assembly Calibration

Calibrating the load limiting control for motor-driven units.

START-UP PROCEDURE

Compressor Oil Preparation and Heating

Preparing compressor oil, including heating and quenching.

Suction Damper, Labyrinth, and Pre-Start Checks

Adjusting damper/labyrinths and performing final pre-start checks.

Machine Start and Running System Checks

Procedures for starting the machine and checking its operation.

Post-Start Procedures

Includes hot alignment, stopping, and adjusting refrigerant charge/levels.

PUMPOUT PROCEDURES

Pumpout Unit Overview and Controls

General information, lubrication, and control settings for pumpout units.

5F Model Pumpout Procedures

Evacuation, transfer, and distillation steps for 5F pumpout units.

6D Model Pumpout Procedures

Evacuation, transfer, and pressurization steps for 6D hermetic units.