ACCESSORIES
KIT NUMBER KIT NAME 24---30 36---30 48---30 60---30
KSASF0101AAA SUPPORT FEET X X X X
KSATX0201PUR TXV (HSO) X
KSATX0301PUR TXV (HSO) X
KSATX0401PUR TXV (HSO) X
KSATX0501PUR TXV (HSO) X
X = Accessory
Infinity Controls DESCRIPTION
SYSTXCCUIZ01--- A Infinity System Zone Control User Interface
SYSTXCCUID01 --- A Infinity System Non---Zone Control User Interface
Note: These Infinity series units must use ---A revision or later to operate properly
ACCESSORY USAGE GUIDELINE
Accessory
REQUIRED FOR
L O W --- A M B I E N T C O O L I N G
APPLICATIONS
(0_Fto55° F)
REQUIRED FOR LONG LINE
APPLICATIONS*
(Over 80 Ft.)
REQUIRED FOR SEA COAST
APPLICATIONS
(Within 2 miles)
Crankcase Heater Standard Standard Standard
Evaporator Freeze Thermostat } Standard with Infinity Control No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay
Not required since compressor
always starts unloaded
Not required since compressor
always starts unloaded
Not required since compressor
always starts unloaded
Low Ambient Control } Standard with Infinity Control No No
Support Feet Recommended No Recommended
Liquid Line Solenoid Valve No
See Long Line
Application Guideline
No
Puron Hard Shutoff TXV Yes{ Yes{ Yes{
Ball Bearing Fan Motor Standard Standard Standard
Winter Start Control } Standard with Infinity Control No No
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differential (250 ft. Total Equivalent Length), refer to Residential Split---System Longline
Application Guideline.
{ Required on all indoor units. Standard on all new Puron fan coils and furnace coils.
} Standard with Infinity Control (non---communicating thermostat is not allowed except for emergency use).
Accessory Description and Usage (Listed Alphabetically)
1. Support Feet
Four stick--on plastic feet that raise the unit 4 in. above the
mounting pad. This allows sand, dirt, and other debris to be
flushed from the unit base, minimizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
2. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube.
Hard shut off types are available.
Usage Guideline:
24ANA124ANA1