Model Number INDOOR MODEL
AHRI STANDARD RATINGS --- COOLING
CAP ACITY
SEER EER
ID CFM
HIGH LOW HIGH LOW
24ANB124A**31 FE5ANB004 26600 24000 21.0 15.0 800 800
24ANB136A**31 FE5ANB004 36000 33200 20.0 14.7 1200 924
24ANB148A**31 FE4ANB006 48000 40000 18.0 13.5 1400 1120
24ANB160A**31 FE4ANB006 58000 46500 16.7 13.2 1625 1300
* AHRI = Air Conditioning, Heating & Refrigeration Institute
EER —
Energy Efficiency Ratio --- 80_F(26.6_C) indoor db/67_F(19.4_C) indoor wb & 95_F(35_C) outdoor wb.
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---DelayRelay. Inmostcases,only1methodshouldbeusedtoachieveTDRfunction.Usingmorethan1methodinasystemmaycausedegradationinperformance.
Use either the a ccessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
UI — User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulat ing fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
24ANB1