30HXC 080-375
30GX 082-358
Screw Compressor
Water-Cooled Liquid Chillers and
Air-Cooled Liquid Chillers
30HXC Nominal cooling capacity 290-1325 kW
30GX Nominal cooling capacity 285-1205 kW
50 Hz
Installation, operation and maintenance instructions
GLOBAL CHILLER

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 30GX Series and is the answer not in the manual?

Carrier 30GX Series Specifications

General IconGeneral
BrandCarrier
Model30GX Series
CategoryChiller
LanguageEnglish

Summary

2- SAFETY CONSIDERATIONS

5- ELECTRICAL DATA 30 HXC

6- ELECTRICAL DATA FOR UNITS WITH HIGH CONDENSING TEMPERATURES

8- ELECTRICAL DATA 30 GX

9- APPLICATION DATA

10 - INSTALLATION

10.1 - Check equipment received

Procedure for inspecting the unit upon receipt for damage or missing parts.

10.2 - Moving and siting the unit

Guidelines for safely moving and positioning the chiller unit.

11 - LIFTING INSTRUCTIONS

11.1 - 30 HXC 080-190

Specific lifting instructions and dimensions for 30HXC models 080-190.

11.2 - 30 HXC 200-285

Specific lifting instructions and dimensions for 30HXC models 200-285.

11.3 - 30 HXC 310-375

Specific lifting instructions and dimensions for 30HXC models 310-375.

11.4 - 30 GX 082-162

Specific lifting instructions and dimensions for 30GX models 082-162.

11.5 - 30 GX 182

Specific lifting instructions and dimensions for the 30GX 182 model.

11.6 - 30 GX 207-267

Specific lifting instructions and dimensions for 30GX models 207-267.

11.7 - 30 GX 298-358

Specific lifting instructions and dimensions for 30GX models 298-358.

11.8 - Piping connections

11.8.1 - Operating precautions

Essential precautions for designing and installing water circuits.

11.8.3 - Freeze protection

Measures for protecting the unit and piping from freezing temperatures.

12 - ELECTRICAL CHARACTERISTICS

12.1 - 30 HXC

Details operating conditions and environmental classification for 30HXC units.

12.2 - 30 GX

Details operating conditions and environmental classification for 30GX units.

13 - RECOMMENDED WIRE SECTIONS

14 - MAJOR SYSTEM COMPONENTS AND OPERATION DATA

15 - MAINTENANCE

15.1 - Refrigerant charging - adding charge

Safe procedures for adding refrigerant to the system.

15.2 - Indication of low charge on a 30 HXC system

How to identify and address low refrigerant charge on 30HXC units.

15.2.1 - To add charge to the 30 HXC systems

Step-by-step guide for adding refrigerant to 30HXC systems.

15.2.2 - Indication of low charge on 30 GX systems

How to identify low refrigerant charge on 30GX systems.

15.4 - Oil charging - low oil recharging

Procedure for adding oil to the system.

16 - START-UP CKECKLIST FOR 30 HXC;GX LIQUID CHILLERS