Service manual
23
8.8.3 Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
A. The defrost time has reached to 7.5 or 10 minutes.
B. The compressor current has reached to I
DEFROST
or above, I
DEROST
differs in different models
8.8.4 Defrosting Actions
8.9 Auto mode
8.9.1
The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
only according to the temp
erature
d
ifference between room temp
erature
(TA) and set temp
erature
(TS)
.
-1
TA-TS
2
Heating (fan only at cooling only) Fan only Cooling
8.9.2 The indoor fan blows automatically in corresponding selected mode
8.9.3 The motion of indoor fan’s blade should accord with the selected operation mode
8.9.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot start for
15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set
temp. varies
8.10 Force cooling function
8.10.1 Select forced cooling function with the forced cooling button or the switch
8.10.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is set
as low, the A/C operates at the DRY mode with a set temp. of 24
8.10.3 All protections of remote control cooling are available at forced cooling operation
8.10.4 Forced Auto function
Select forced auto function with the forced auto button or the switch.In forced auto status the A/C operates at
remote control mode with a set temp. of 24