5
 
*Fan motor with ball bearings required.
† Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 036 and 042, Series 30; 048, 060 Series 30, 
31 single phase; and all 3-phase units). Do not use hard shutoff TXV with liquid solenoid valve.
N/A — Not Applicable
 
Accessory usage guideline
 
* For tubing line sets between 50 and 175 ft, refer to Residential’s Split Systems Long-Line Application Guideline.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.
 
Accessory description and usage (Listed alphabetically)
 
1. Ball Bearing Fan Motor
 
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. 
SUGGESTED USE:  Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
 
2. Coastal Filter 
 
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 
SUGGESTED USE:  In geographic areas where salt damage could occur.
 
3. Compressor Start Assist — Capacitor and Relay
 
Start capacitor and start relay gives ‘‘hard’’ boost to compressor motor at each start-up. 
SUGGESTED USE:  Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.
 
4. Compressor Start Assist — PTC 
 
Solid-state electrical device which gives a ‘‘soft’’ boost to the compressor at each start-up. 
SUGGESTED USE:  Installations with marginal power supply.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
 
5. Crankcase Heater 
 
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on 
restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. 
SUGGESTED USE:  When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with low-ambient controller.)
All commercial installations.
 
THERMOSTAT PKG. DESCRIPTION
TSTATCCNAC01-B
 
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
 
TSTATCCPAC01-B Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCBAC01-B Builder’s Thermostat, Manual Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCSEN01-B Outdoor Air Temperature Sensor
TSTATXXNBP01 Backplate for Non-Programmable Thermostat
TSTATXXPBP01 Backplate for Programmable Thermostat
TSTATXXBBP01 Backplate for Builder’s Thermostat
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) — 10 Pack
ACCESSORY
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Ye s N o N o
Winter Start Control Yes† No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay Yes Yes No
MotorMaster® Control 
or 
Low-Ambient Pressure Switch Ye s N o N o
Wind Baffle
See low-ambient
instructions No No
Coastal Filter No No Yes
Unit Risers Recommended No Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV No
See
Long-Line
Application Guideline No
Ball Bearing Fan Motor Yes‡ No No