94 Specifications subject to change without notice. SG-38MARB-01
PCB Board 5
Procedure Illustration
1) Loosen the hooks (4) then open the
electronic control box cover.
2) Disconnect the fan motor connector
from the eletronic control board.
3) Remove the compressor connector.
4) Pull out the two blue wires
connected to the 4-way valve.
5) Pull out the condenser connectors
coil temp. sensor(T3),outdoor
ambient temp. sensor(T4) and
discharge temp. sensor(TP).
6) Disconnect the electronic expansion
valve wire.
7) Remove the electronic control board.
Reactor
DR
T3, T4, TP
Compressor
Electronic Expansion Valve
4-Way Valve