EasyManua.ls Logo

Carrier 38MGQ Series - Page 35

Carrier 38MGQ Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
Fig. 31 DC voltage test
Fig. 32 Reactor resistance test
Remark
Use a multimeter to test the DC voltage between the L2 port and S
ports of the outdoor unit. (Fig. 31) The red pin of multimeter
connects with the L2 port while the black pin is for the S port.
When the AC is running normally, the voltage will move
alternatively between --50V to 50V.
If the outdoor unit has a malfunction, the voltage moves
alternatively with a positive value.
If the indoor unit has a malfunction, the voltage will be a certain
value. Example: 10-- 13VDC small fluctuating amounts indicates
indoor unit malfunction.
Remark
Use a multimeter to test the resistance of the reactor which does not
connect with the capacitor (Fig. 32).
The normal values should be around zero ohm.
Otherwise, the reactor must have a malfunction and must be
replaced.