38MGQ / 40MAQ / 40MBC / 40MBD / 40MBF
Multi---Zone Ductless Syst em
Sizes 18K, 24K, 30K, 36K and 48K
Installation Instructions
NOTE: Read the entire instruction manual before starting the installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 2.........................
GENERAL 2.........................................
PIPING REQUIREMENTS 3............................
ELECTRICAL DATA 4................................
DIMENSIONS 6 --12...................................
CLEARANCES 13 --15.................................
INSTALLATION GUIDE 16.............................
INSTALLATION TIPS 16...............................
HIGH WALL INDOOR UNIT INSTALLATION 16...........
CASSETTE INDOOR UNIT INSTALLATION 18............
INDOOR UNIT MAIN BODY INSTALLATION 18..........
INDOOR UNIT INSTALLATION 19......................
DUCTED INDOOR UNITS INSTALLATION 24............
FAN PERFORMANCES (DUCTED UNITS) 28.............
FLOOR CONSOLE INDOOR UNIT INSTALLATION 30.....
INSTALLING THE INDOOR UNIT 31....................
OUTDOOR UNIT INSTALLATION 32....................
START--UP 35........................................
CONNECTION DIAGRAMS 36.........................
OUTDOOR UNIT DIAGNOSTIC GUIDES 38..............
Question and Answer IconNeed help?

Do you have a question about the Carrier 38MGQ and is the answer not in the manual?

Carrier 38MGQ Specifications

General IconGeneral
RefrigerantR-410A
Cooling Capacity9, 000 - 36, 000 BTU/h
Power Supply208-230V/1Ph/60Hz
Operating Temperature (Heating)Down to -13°F
Sound Pressure Level (Indoor)19 - 56 dB
Sound Pressure Level (Outdoor)50 - 60 dB
Indoor Unit Dimensions (H x W x D)Varies by model
Outdoor Unit Dimensions (H x W x D)Varies by model
Indoor Unit WeightVaries by model
Outdoor Unit WeightVaries by model

Summary

Safety Considerations

Electrical Shock Hazard Warning

Warning about electrical shock during installation or service.

Equipment Damage Hazard Caution

Caution regarding potential equipment damage due to improper installation or operation.

Piping Requirements

Refrigerant Line Specifications

Details minimum/maximum lengths, height differences, pipe sizes, and refrigerant charge.

Electrical Data

Wiring and Connection Guidelines

Power and Communication Wiring

Recommended methods for connecting power and communication wiring, including wire types and insulation.

Indoor Unit Clearances

Outdoor Unit Clearances

Installation Guide

High Wall Indoor Unit Installation

Install Mounting Plate

Steps for attaching the mounting plate to the wall for high wall indoor units.

Drill Hole for Piping, Drain, and Wiring

Instructions on drilling wall holes for refrigerant lines, drain, and wiring connections.

Install Power, Piping, and Wiring to Indoor Unit

Indoor Unit Installation Steps

Detailed procedure for physically mounting and connecting the indoor unit with power and piping.

Cassette Indoor Unit Installation

Main Body Installation

Steps for installing the main body of the cassette indoor unit, including ceiling opening and hook installation.

Indoor Unit Installation Procedures

Drain Piping Work

Detailed steps for installing the drain piping to ensure proper water flow and prevent condensation.

Test Operation

Test Operation After Decoration Panel Install

Procedures for performing test operations after the decoration panel is installed.

Start-Up Procedures

Test Operation

Procedure to perform test operation after completing gas leak and electrical safety checks.

System Checks

Verification of tubing, connections, and wall seals after installation.

Ducted Indoor Unit Installation

Installation Location Requirements

Site selection criteria for ducted indoor units, including structural strength and environmental factors.

Install Indoor Ducted Unit

Steps for installing the ducted indoor unit, including hanger bolts and unit placement.

Air Supply Duct Installation

Return Air Duct Installation

Floor Console Indoor Unit Installation

Refrigerant Piping and Drain Piping

Guidelines for installing refrigerant piping and drain piping for floor console units.

Installing the Indoor Unit

Outdoor Unit Installation

Base Support, Leveling, and Wind Protection

Instructions for installing the outdoor unit on a stable base, ensuring it's level and protected from wind.

Outdoor Unit Piping Connections

Important notes on using correct tubing types and ensuring sufficient piping length for outdoor unit connections.

Outdoor Unit Wiring and Connections

Install Power and Interconnecting Wiring to Outdoor Unit

Steps for wiring the outdoor unit, including power supply, disconnects, and conduit connections.

Indoor Unit Wiring and Piping

Install Power, Interconnecting Wiring, and Piping to Indoor Unit

Steps for connecting power, wiring, and piping for each indoor unit.

System Vacuum and Charge

Deep Vacuum Method Procedure

Procedure for achieving a deep vacuum using specialized equipment to remove air and moisture.

Triple Evacuation Method Procedure

Alternative method for system evacuation using nitrogen, suitable for pumps not achieving deep vacuum.

Connection Diagrams

Size 18 Connection Diagram

Wiring diagram showing connections for a Size 18 outdoor unit with multiple indoor units.

Size 27 Connection Diagram

Wiring diagram for a Size 27 outdoor unit, illustrating connections to indoor units.

Connection Diagrams (Continued)

Size 36 Connection Diagram

Wiring diagram for a Size 36 outdoor unit, showing connections to multiple indoor units.

Size 48 Connection Diagram

Wiring diagram for a Size 48 outdoor unit, detailing connections to indoor units and notes on wiring.

Diagnostic Guides

Indoor Unit Error Codes

Table listing indoor unit error codes, display patterns, and LED status for troubleshooting.

Outdoor Unit Error Codes

Table listing outdoor unit error codes and corresponding indoor unit error references for diagnostics.