EasyManua.ls Logo

Carrier 38MGRBQ18B-3 - Page 93

Carrier 38MGRBQ18B-3
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38MGRBQ: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
93
4 COMPRESSOR REMOVE THE COMPRESSOR REMARKS
1. Perform the steps from sections 1, 2, and 3.
2. Remove the electrical control box and the partition plate.
3. Extract the refrigerant gas.
4. Remove the sound insulation material and crankcase
heating cable.
5. Remove the compressor terminal cover, and disconnect the
compressor thermo wires and compressor from the
terminal.
6. Remove the discharge pipe and suction pipe with a burner.
7. Remove the hex nuts and washers securing the compressor
to the bottom plate
8. Lift the compressor.
5 REACTOR REMOVE THE REACTOR REMARKS
1. Perform the steps from sections 1 and 2.
2. Loosen the connector between the IPM and reactor.
3. Remove 2 screws of the inductance cover, then remove the
inductance cover.
4. Disconnect two pieces of wires connected from the
inductance cover.
5. Remove the 4 reactor screws, then remove the reactor.
6 4-WAY VALVE REMOVE THE 4-WAY VALVE REMARKS
1. Perform the steps from sections 1 and 2.
2. Extract the refrigerant gas.
3. Remove the electrical parts as described in section 3.
4. Remove the coil screw, then remove the coil.
5. Detach the welded parts of the 4-way valve and pipe.
Inductance
Cover
Screws
Reactor
Screws
Coil
Welded
Parts