Carrier 38MPRA Series - CLEARANCES

Carrier 38MPRA Series
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Specifications subject to change without notice. SG-38MPRA-02
CLEARANCES
Fig. 3 — Clearances
Table 4 — Clearances
NOTE: The outdoor unit must be mounted at least 2in (50mm) above the maximum anticipated snow depth.
Fig. 4 —Clearances for multiple units
A
D
B
Air outlet
Air inlet
C
E
UNIT MINIMUM VALUE IN. (MM)
A 24 (609)
B 24 (609)
C 24 (609)
D 4 (101)
E 4 (101)
118in (300cm) or more
19in (48cm) or more
on a multiple parallel
unit arrangement
4in (10cm) or more on
a single parallel unit
arrangement
24in (60cm)
or more
59in (150cm)
or more on a
multiple parallel
unit arrangement
24in (61cm) or more
on a single parallel
unit arrangement
9.8in (25cm)
or more for
24in (61cm) or
more is
recommended
for service
9.8in (25cm)
24in (61cm)
or more is
recommended
for service