Do you have a question about the Carrier 50AH and is the answer not in the manual?
| Model | 50AH |
|---|---|
| Type | Ceiling Fan |
| Number of Blades | 3 |
| Air Delivery | 210 CMM |
| Blade Span | 1200 mm |
| Warranty | 2 years |
Highlights compact design, flexibility, easy maintenance, high quality, and quiet scroll compressor technology.
Describes the 'ROOMTOP' unit's compact, low-silhouette design for easy indoor ceiling installation.
Covers application flexibility, quiet operation with noise reduction, and easy maintenance access.
Explains the structure and meaning of the 50AH unit model number designation.
Presents cooling capacity ratings according to ARI standards for different unit sizes.
Details factory testing, safety controls, and overall reliability of the 50AH ROOMTOP® units.
Provides detailed physical specifications including weight, refrigerant, compressor, coil, and fan data.
Shows the distribution of operating weight at each corner of the unit and overall dimensions.
Includes thermostats, Time Guard II circuit, and electric heater modules for enhanced control and heating.
Covers condensate pumps, head pressure control dampers, and vibration isolators for improved operation.
Provides detailed dimensional drawings and measurements for the 50AH unit.
Illustrates the physical layout and access points for major components within the unit.
Guides users through determining cooling requirements and selecting the appropriate unit size.
Presents tables of total and sensible cooling capacities for various operating conditions.
Provides performance data for evaporator fans, including ESP and Fan kW for different CFM.
Details performance for optional belt drive evaporator fan motors.
Shows condenser fan performance data, including pulley turns and fan kW for different static pressures.
Lists static pressure drops associated with electric heater modules for various airflow rates.
Explains the cooling sequence, continuous fan operation, and control features.
Details branch circuit requirements (MCA, MOCP) for electric heater modules.
Illustrates the electrical connections for 230-1-60 units, including component arrangement and legend.
Shows electrical connections for 208/230-3-60 units, including component arrangement and legend.
Provides a diagram for typical refrigerant piping and wiring connections.
Specifies the minimum and maximum outdoor temperatures for unit operation with or without head pressure control.
Details instructions for splitting the unit sections and maximum refrigerant tubing lengths.
Outlines system description, certifications, quality assurance, delivery, storage, and handling.
Details unit cabinet, fans, compressor, coils, refrigerant components, and filter section.
Specifies control system features, safety devices, and Time Guard II functionality.
Covers operating characteristics using R-22 and electrical requirements for single point connection.
Details electric heat module features and the thermostat assembly with malfunction light.
Describes Time Guard II delay, condensate pump, head pressure control, and vibration isolation packages.