Copyright 2005 Carrier Corporation Form 42B-1PD
Carrier’s versatile belted fan coil units
satisfy design requirements:
A selection of 8 sizes covers
capacities from 600 to 4000 cfm
Choice of motors, from
1
/
4
to 5 hp,
eliminates oversizing
Wide range of coil options for 2-pipe
or 4-pipe systems
Optional DX coils with expansion
valve and distributor
Single and three-phase electric
heat (1.0 to 40 kW)
Features/Benefits
The 42BHC, BVC belt drive
fan coil units provide year-
round comfort air
conditioning with central
station operating economy.
A variety of coil options
reduces first cost
Four, 6 or 8-row cooling coils combine
needed capacities with the most effi-
cient heat transfer surface. For
4-pipe systems, select either of two
split-coil options. Coils consist of alu-
minum fins securely bonded to
1
/
2
-in.
OD seamless copper tubes. Each fin’s
aluminum collar ensures accurate con-
trol of the fin spacing, while complete-
ly covering the tubes to lengthen coil
life. All coils also feature manual air
vents, with automatic air vent available
as an option.
AIRSTREAM™
42BHC,BVC
System Fan Coils
600to4000Cfm
Product
Data
42BHC UNIT
42BVC UNIT
Question and Answer IconNeed help?

Do you have a question about the Carrier AIRSTREAM 42BHC and is the answer not in the manual?

Carrier AIRSTREAM 42BHC Specifications

General IconGeneral
BrandCarrier
ModelAIRSTREAM 42BHC
CategoryFan
LanguageEnglish

Summary

Product Features and Benefits

Overview of Features and Benefits

Introduces the 42BHC, BVC belt drive fan coil units and their benefits for year-round comfort.

Unit Design and Construction

Low Operating Cost Fan Wheel Design

Details on fan wheel design for efficient operation and reduced vibration, ensuring low operating costs.

Durable Construction for Easy Maintenance

Describes the heavy-gage galvanized steel casing and removable side panels for accessibility.

Model Nomenclature and Physical Data

Model Number Nomenclature

Explains the coding system used for 42BHC and 42BVC fan coil unit model numbers.

Physical Data Tables

Provides tables with unit physical specifications, including shipping weights and dimensions.

42BHC Base Unit Dimensions

42BHC Fan Coil with Motor Control Dimensions

42BVC Fan Coil Base Unit Dimensions

42BVC Fan Coil with Motor Control Dimensions

42BVC Fan Coil with Electric Heat Dimensions

Application Data

Piping Component Data

Details on piping components, including air vents, swage, and circuit setters, with Cv factors and ratings.

Unit Selection Procedure

Formulas for Performance Calculation

Provides formulas for calculating unit capacity and water pressure drop.

Step-by-Step Selection Example

Illustrates the process of selecting a unit and determining its performance with an example.

Motor and Drive Selection Guidance

Explains how to calculate total static pressure and select the appropriate motor and drive.

Performance Data: Correction Factors

Performance Data: Horsepower and Static Resistance

Unit Horsepower Data Table

Tables showing required motor horsepower based on CFM and total static pressure.

Typical Wiring Schematics: Single-Phase

Base Unit Single-Phase Wiring

Illustrates wiring for the base unit in single-phase power configurations.

Motor Control Single-Phase Wiring

Shows wiring for motor control and disconnect options in single-phase power.

Typical Wiring Schematics: Three-Phase

Base Unit Three-Phase Wiring

Illustrates wiring for the base unit in three-phase power configurations.

Motor Control Three-Phase Wiring

Shows wiring for motor control and disconnect options in three-phase power.

Typical Wiring Schematics: Thermostat Connections

Electrical Data: Heater and Motor Information