SG-38MPRA-02                      Specifications subject to change without notice.                      19
Silence
Press SILENCE on the remote controller to enable the SILENCE
function. While  this  function  is  active,  the  indoor  unit  runs  at  faint
breeze  (1%  fan  speed),  which  reduces  noise  to  the  lowest  possible
level.
Occupancy Sensor (Sizes 09K-12K)
With  the  built-in  infrared  sensor,  the  indoor  unit  detects  human
movement. The compressor operates in a low frequency if you leave
the  room  for  30  minutes.  The  compressor  operates  in  a  lower
frequency  if  you  leave  the  room  for  120  minutes,  and  resumes
automatically when you come back, which helps save energy.
Information Inquiry
To enter information inquiry status, complete the following procedure
within ten seconds:
• Press LED 3 times.
• Press SWING 3 times. If successful, you will hear beeps for two
seconds.
• Use LED and SWING to cycle through the information displayed.
• Press LED to display the next code in the sequence.
• Press SWING to display the previous code.
Table 16 displays the information codes. The screen displays the code
for two seconds, then the information for 25 seconds.
Table 16 — Information Codes
DISPLAYED CODE EXPLANATION ADDITIONAL NOTES
T1 T1 T1 temperature
T2 T2 T2 temperature
T3 T3 T3 temperature
T4 T4 T4 temperature
TP TP TP temperature
Targeted Frequency FT Targeted Frequency
Actual Frequency TR Actual Frequency
Compressor Current dL N/A
Outdoor AC Voltage UO N/A
Indoor capacity test Sn N/A
Reserve -- Running mode
Outdoor Fan Speed Pr Outdoor fan speed
EXV opening angle LR EXV opening angle
Indoor fan speed IR Indoor fan speed
Indoor humidity HU N/A
Adjusted setting temperature TT N/A
Indoor dust concentrations DT N/A
Wi-Fi signal strength IF N/A
GA algorithm frequency OT N/A