– 18 –
FILE NO. SVM-07018
5. SPECIFICATION OF ELECTRICAL PARTS
5-1. Indoor Unit
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-20-4BR AC Motor with 150°C thermo fuse
2 Thermo. sensor (TA-sensor) ——— 10 kΩ at 25°C
3 AC-AC transformer (T01) TT-10 187 - 276V, 6VA
4 Microcomputer
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27 mH, 600mA
7 Diode (DB01) KBP06M 1.5A, 420V
8 Capacitor (C50) 2200µF, 35 V
9 Fuse (F01) BET 3.15A, 250VAC T3.15A, 250 V
10 Regulator IC (IC08) NJM7812 12VDC, 1.5A max
11 Regulator IC (IC11) NJM7805 5VDC, 1.5A max
12 Varistor (R04) TND15G561K 560V
13 Louver motor MP24ZT DC 12V
5-2. Outdoor Unit (38NYV009E, 38NYV012E)
No. Parts name Model name Rating
1 SC coil L01 GET-04051 0.6mH, 15A
(Noise filter) L03 GET-04052 2.0mH, 10A
Primary side DC280V, Secondary2 DC-DC transformer
SWT-72
side 7.0 V x 1, 12 V x 1, 17V x 2
3 Reactor CH-51-Z-T L=19mH, 10A
4 Outside fan motor
SKF-240-20B-1 20W
5
G5NB-1A Coil DC12V Contact AC250V-1.5A
6
Outside air temp.
(Inverter attached) 10kΩ (25°C)
sensor (TO sensor)
7
Heat exchanger temp.
(Inverter attached) 10kΩ (25°C)
sensor (TE sensor)
9
JX0-6B
30A, 600VAC
Terminal block (6P)
10
11
Fuse
For protection of switching power source 3.15A, AC250V
For protection of inverter input overcurrent 25A, AC250V
12
Electrolytic capacitor LLQ2G501KHUBTF 500µF, DC 400 V x 3 pieces
13
Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
Rectifier
14
Fan control relay
D15XB60-7001 15A, 600V
16 Coil-V-4way −
AC220-240V
ELXV350ELL222ML35S
µPD780024AGK
IGBT GT15J321(Q) 15A, 600
Compressor DA89X1C-23FZ 3-phases 4-poles 750W
15
8
Dischenge temp.
(Inverter attached) 62kΩ (20°C)
sensor (TD sensor)