36
FILE NO. SVM-07018
9-1-1. Installation Diagram of Indoor and Outdoor Units
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
Wall
Do not allow the drain hose
to get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping hole
sloped slightly
Shield
pipe
A
ir
f
ilt
e
r
H
o
o
k
Hook
(A
tta
c
h
to
th
e
fr
o
n
t p
a
n
e
l.)
65 mm or more
170 m
m
or m
ore
1 Installation
plate
170 mm or more
Active Carbon
Cleaning filter
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Bottom right
Left
Rear left
Bottom left
Insulate the refrigerant
pipes separately with
insulation, not together.
6 mm thick heat resisting
polyethylene foam
Before installing the
wireless remote control
With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
22
22
2 Wireless remote control
33
33
3 Batteries
Pan head wood screw
4
Remote control holder
2
Wireless remote control
5
7
100 mm or more
B mm or more
A mm or more
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
1
0
0
m
m
o
r m
o
re
Extension
drain hose
(Not available,
provided by
installer)
600 mm or more
Drain outlet
Air outlet
38NYV012E 38NYV009E
600 mm 400 mm
100 mm 45 mm
A
B