FILE NO.SVM-07013
6. SPECIFICATIONS OF ELECTRICAL PARTS
No.
 Fan motor 
 (for indoor)   
42NQV045H, 42NQV045M
DC 340V, 30W
2 Room temp. sensor (TA-sensor)
 10k
Ω
 at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
 10kΩ at 25°C
4 Louver motor  Output (Rated) 1W, 16 poles, DC12V 
( −  )
( 
−
 )
MP24Z3T
Parts name
1
 ICF-340-30-2
SpecificationsType
42NQV035M
MMF-240-20-4B       AC240/220V, 20W
42NQV025H, 42NQV035H,
6-1.  Indoor Unit
No.
1  Reactor L = 10mH, 16A 
2  Outdoor fan motor  DC140V, 43W
3  Suction temp. sensor (TS sensor)
 10kΩ (25°C)
4  Discharge temp. sensor (TD sensor)
 62kΩ (20°C)
5 Outside air temp. sensor (TO sensor)
 10kΩ (25°C)
6  Heat exchanger temp. sensor (TE sensor)
 10kΩ (25°C)
7  Terminal block (6P)  30A, AC600V
38NYV025H,38NYV035M
 Compressor  3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ
DA111A1F-20F1
Parts name Model name Rating
CH-57
ICF-140-43-4R
 11    Compressor thermo
 
PW-2AL    OFF : 125±4°C, ON : 90±5°C
38NYV045H
38NYV035H,38NYV045M
9     COIL FOR P.M.V. 
 C12A01A              DC12V
10    Coil for 4-way valve 
 VHV                  AC220-240V
6-2.  Outdoor Unit
 −  20 −