4
Accessories
* Fan motor with ball bearings required.
† See low-ambient controller Installation Instructions for application.
‡ Do not use hard shutoff TXV with Liquid-Line Solenoid Valve. Use only these specified components.
Accessory usage guideline
* For Tubing line sets greater than 50 ft, refer to Residential Split System Long-Line Application Guideline and Service Manual.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.
ORDERING NO. DESCRIPTION
KAATD0101TDR
Time-Delay Relay — All Sizes
KSALA0301410
Low-Ambient Pressure Switch — All Sizes
P251-0083 (RCD)
Low-Ambient Controller — All Sizes
32LT660004* (RCD)
MotorMaster® Control — All Sizes
KAAFT0101AAA†
Evaporator Freeze Thermostat — All Sizes
KAAWS0101AAA†
Winter Start Control — All Sizes
KSACY0101AAA
Cycle Protector — All Sizes
KSAHS1501AAA
Start Assist — Capacitor and Relay — All Sizes
KAACS0201PTC
Start Assist — PTC — Standard on Size 024 Series 30 and all Series 32
KAACH1201AAA
Crankcase Heater — All Sizes
KSATX0201HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Sizes 024, 030 (Factory Supplied)
KSATX0301HSZ‡
Thermostatic Expansion Valve (Hard Shutoff) — Sizes 036, 042 (Factory Supplied)
KSAPX0101PIS
Piston Body — All Sizes
HC38GE231 (RCD)
Ball Bearing Fan Motor — All Sizes
KH45LG140 (RCD)
Filter Drier (Suction Line) — Sizes 024–036
KH45LG141 (RCD)
Filter Drier (Suction Line) — Size 042
KAALS0201LLS‡
Liquid-Line Solenoid Valve — All Sizes
KSASF0101AAA
Support Feet — All Sizes
KAACF0801MED
Coastal Filter — All Sizes
THERMOSTAT/SUBBASE PKG DESCRIPTION
TSTATCCNAC01-B
Thermostat — Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCPAC01-B
Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATCCPRH01-B
Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control
TSTATCCBAC01-B
Builder’s Thermostat — Manual Changeover, Non-Programmable, °F/°C, 1 Stage Heat,
1-Stage Cool
TSTATCCSAC01
Thermostat — Manual Changeover, 5-2 Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATXXSEN01-B
Outdoor Air Temperature Sensor
TSTATXXNBP01
Backplate for Non-Programmable Thermostat
TSTATXXPBP01
Backplate for Programmable Thermostat
TSTATXXBBP01
Backplate for Builder’s Thermostat
TSTATXXSBP01
Backplate for Standard Thermostat
TSTATXXCNV10
Thermostat Conversion Kit (4 to 5 wire) — 10 Pack
ACCESSORY
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
Crankcase Heater
Yes Yes No
Evaporator Freeze Thermostat
Ye s N o N o
Winter Start Control
Ye s †
No No
Accumulator
No No No
Compressor Start Assist —
Capacitor and Relay
Yes Yes No
Low-Ambient Controller,
MotorMaster® Control,
or
Low-Ambient Pressure Switch
Ye s N o N o
Wind Baffle
See Low-Ambient Instructions No No
Coastal Filter
No No Yes
Support Feet
Recommended No Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
No
See Long-Line
Application
Guideline No
Ball Bearing Fan Motor
Ye s ‡
No No