22
Detailed cooling capacities* continued
See notes on pg. 24.
EVAP
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh†
Total
Sys
KW**
Capacity
MBtuh†
Total
Sys
KW**
Capacity
MBtuh†
Total
Sys
KW**
Capacity
MBtuh†
Total
Sys
KW**
Capacity
MBtuh†
Total
Sys
KW**
Capacity
MBtuh†
Total
Sys
KW**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
38TXA048-30 Outdoor Section With CC5A/CD5AA060 Indoor Section
1400
72 53.0 25.6 2.87 51.3 25.0 3.18 49.4 24.3 3.53 47.2 23.6 3.93 44.8 22.8 4.36 42.1 21.9 4.83
67 50.3 33.2 2.85 48.0 32.2 3.16 45.8 31.4 3.51 43.5 30.5 3.89 41.0 29.6 4.32 38.4 28.6 4.80
63†† 47.2 32.8 2.84 45.0 31.8 3.14 42.8 30.9 3.49 40.5 29.9 3.88 38.1 28.8 4.30 33.9 27.0 4.76
62 46.2 40.4 2.83 44.0 39.3 3.14 41.5 38.1 3.48 38.9 36.8 3.86 36.1 35.3 4.28 33.2 33.2 4.75
57 42.3 42.3 2.81 40.1 40.1 3.12 38.0 38.0 3.46 36.7 36.7 3.85 35.2 35.2 4.28 33.6 33.6 4.75
1600
72 53.9 26.4 2.94 52.2 25.9 3.26 50.2 25.2 3.61 48.0 24.5 4.00 45.5 23.8 4.44 42.4 22.6 4.90
67 51.1 34.7 2.92 48.7 33.7 3.23 46.5 32.9 3.58 44.1 32.2 3.96 41.6 31.3 4.39 38.8 30.4 4.86
63†† 48.1 34.5 2.91 45.8 33.5 3.22 43.7 32.8 3.57 41.3 31.7 3.95 38.7 30.6 4.37 34.4 28.8 4.83
62 47.2 43.0 2.91 45.1 42.0 3.22 42.4 40.6 3.56 39.7 39.0 3.94 37.0 37.0 4.36 34.5 34.5 4.83
57 45.0 45.0 2.89 42.6 42.6 3.20 40.4 40.4 3.55 39.0 39.0 3.93 37.5 37.5 4.36 35.4 35.4 4.83
1800
72 53.7 26.7 3.00 52.9 26.7 3.33 50.9 26.1 3.68 47.9 25.0 4.06 45.6 24.3 4.50 42.3 23.1 4.96
67 51.5 35.9 2.99 49.5 35.3 3.30 47.2 34.6 3.65 44.8 33.9 4.04 42.0 32.8 4.46 39.1 31.9 4.93
63†† 48.6 35.9 2.97 46.5 35.1 3.29 44.4 34.5 3.64 41.9 33.4 4.02 39.2 32.3 4.45 35.2 30.6 4.91
62 47.8 45.0 2.97 45.7 44.1 3.29 43.1 42.6 3.63 40.5 40.5 4.02 39.0 39.0 4.45 36.7 36.7 4.92
57 46.6 46.6 2.97 44.8 44.8 3.28 42.5 42.5 3.63 41.1 41.1 4.02 39.0 39.0 4.45 36.7 36.7 4.92
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Cooling
Indoor
Section Size
Cooling
Capacity Power Capacity Power
CC5A/CD5AA 060 1.00 1.00 CC5A/CD5AW 048 0.99 1.00
CC5A/CD5AC 048 0.97 0.99 060 1.01 0.99
CC5A/CD5AW 048 0.99 1.00 CD5AA 048 0.99 1.00
060 1.01 1.00 CE3AA 048 1.00 1.01
CD5AA 048 0.99 1.00 060 1.01 1.00
CE3AA 048 1.00 1.00
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
060 1.01 1.01 CC5A/CD5AA 060 1.00 1.00
CF5AA 048 0.99 0.99 CC5A/CD5AC 048 0.97 1.00
CJ5A/CK5A/CK5BA 048 0.99 1.00 CC5A/CD5AW 048 0.99 1.00
060 1.00 1.00 060 1.01 0.99
CJ5A/CK5A/CK5BN 048 0.95 1.00 CD5AA 048 0.99 1.00
060 0.98 1.01 CE3AA 048 1.00 1.01
CJ5A/CK5A/CK5BW 048 0.99 1.00 060 1.01 1.00
CJ5A/CK5A/CK5BX 060 1.01 1.01 CJ5A/CK5A/CK5BA 060 1.00 1.00
CK3BA 048 0.99 1.00 CJ5A/CK5A/CK5BN 060 0.98 1.00
060 1.00 1.00 CJ5A/CK5A/CK5BX 060 1.02 1.00
F(A,B)4AN(F,B) 048 0.99 1.02 CK3BA 060 1.00 1.00
060 0.98 1.04
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
FB4ANB 070 1.01 1.02 CC5A/CD5AA 060 1.00 1.00
FC4BN(F,B) 048 1.02 1.02 CC5A/CD5AC 048 0.97 1.00
FG3AAA 048 0.99 1.00 CC5A/CD5AW 048 0.99 1.00
060 1.00 1.00 060 1.01 0.99
FK4CNB 006 1.02 0.93 CD5AA 048 0.99 1.00
006*** 1.01 0.93 CE3AA 048 1.00 1.01
FV4ANB 006 1.02 0.93 060 1.001 1.00
FX4ANB 060 1.01 1.04 CJ5A/CK5A/CK5BA 060 1.00 0.99
FX4ANF 048 0.99 1.03 CJ5A/CK5A/CK5BW 048 0.99 0.99
COILS + 58MVP080-20 VARIABLE SPEED FURNACE CJ5A/CK5A/CK5BX 060 1.02 0.99
CC5A/CD5AA 060 1.00 1.00 CK3BA 048 0.99 0.99
CC5A/CD5AC 048 0.97 1.00 060 1.00 0.99

Other manuals for Carrier 38TXA