EasyManua.ls Logo

Carrier 38TZA - Physical Data

Carrier 38TZA
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Physical data
* For tubing sets greater than 50 ft, consult Residential Split System Long-Line Application Guideline and Service Manual.
NOTE:
See unit Installation Instructions for proper installation.
ACCURATER
®
PISTON CHART
* Piston listed is for any approved non-capillary tube coil combination. Piston is
shipped with outdoor unit and must be installed in approved indoor coil.
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE
*
)
* Must be a Puron® (R-410A) approved hard shutoff TXV.
UNIT SIZE-SERIES
024-30, 32
030-30, 32 036-30, 32 042-30, 32 048-30, 32 060-30, 32
Operating Weight (Lb)
220 218 221 224 226 284
COMPRESSOR
Copeland
Manufacturer
Type
Scroll
REFRIGERANT
Puron® (R-410A)
Control
AccuRater® (Bypass Type)
Charge (Lb)
5.31 5.19 5.43 5.43 5.75 8.00
COND FAN
Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM)
1800 2400 2400 2800 2800 3300
Motor HP
1/5 1/8 1/8 1/5 1/5 1/4
Motor RPM
825 825 825 825 825 1100
COND COIL
Copper Tube, Aluminum Plate Fin
Face Area (Sq ft)
12.2 12.2 12.2 12.2 12.2 18.2
Fins per In.
25 25 25 25 25 25
Rows
111111
Circuits
222223
VALVE CONNECT. (In. ID)
Sweat
Vapor
5/8 3/4 3/4 7/8 7/8 7/8
Liquid
3/8
REFRIGERANT TUBES* (In. OD)
Vapor (0–50 Ft Tube Length)
5/8 3/4 3/4 7/8 7/8 1-1/8
Vapor (Max Diameter for Long-
Line Applications)
3/4 7/8 7/8 1-1/8 1-1/8 1-1/8
Liquid (0–50 Ft Tube Length)
3/8
Liquid (For Long-Line
Applications)
3/8
UNIT SIZE-SERIES
PISTON*
IDENTIFICATION NO.
024-30, 32
61
030-30, 32
63
036-30, 32
67
042-30, 32
76
048-30, 32
80
060-30, 32
90
UNIT SIZE-SERIES REQUIRED SUBCOOLING (°F)
024-30, 32
8
030-30, 32
11
036-30, 32
11
042-30, 32
9
048-30, 32
10
060-30, 32
11

Related product manuals