E9 OR E.9.: EEPROM ERROR
DEFINITION
E9: EEPROM damage
E.9.: Unmatched data for EEPROM
POSSIBLE CAUSES
Chip or main board damaged
Wrong software in EEPROM
Wrong EEPROM mode
Fig. 48 —E9 or E.9 Troubleshooting Chart
EA: DC FANS STAY AT ZONE A FOR MORE THAN FIVE MINUTES IN HEATING MODE
DEFINITION
Low pressure is too high even though the fan step minimum is T3 > 75°F.
POSSIBLE CAUSES
Operation temperature is too high
Temperature sensor (T3) error
4-Way valve cannot switch successfully
Damaged main board
A210284
Fig. 49 —EA Troubleshooting Chart
*A Refer to resistance table of ambient temperature sensor in Appendix.