Table IV: Components required for a complete installation
Name Specification
Connection pipe 40KQM012 Ø (3/8) 9.52mm (Gas) / Ø (1/4) 6.35mm (Liquid)
40KQM015 Ø (1/2) 12.7mm (Gas) / Ø (1/4) 6.35mm (Liquid)
Wall sleeve
Wall cap
Finishing tape PVC
film
Fastening tape
Tube insulation
Drain hose
I.D. 16 - 17 mm
Sealer putty
- Electrical connecting cable 1. Cable type: H07RN-F, synthetic rubber insulation with Neoprene coating,
between indoor and outdoor unit according to EN 60335-2-40 standards.
Technical data
Table II:
Material supplied
Description Quantity Use
Installation instructions 1 Indoor unit installation
Owner's Manual 1 Correct use
Fresh air intake baffle 1 Air renewal
Note:
For power supply wire size and delay type fuses, refer to the outdoor unit
installation instructions.
Table I: Nominal data
POWER INPUT (WATT)
Heat pump
Unit Cooling Heating
40KQM012 60W 60W
40KQM015 95W 95W
Table III: Operating limits
Cooling / Heating Refer to outdoor unit installation manual.
Nominal single-phase voltage 230V
~
50Hz
Main power supply
Operating voltage limits min. 198V max. 264V
220V
~
60Hz
min. 198V max. 242V