IPM Continuity Check
1. Turn off the outdoor unit and disconnect the power supply.
2. Discharge the electrolytic capacitors and ensure the energy-storage unit(s) have been discharged.
3. Disassemble the outdoor PCB or disassemble the IPM board.
4. Measure the resistance value between P and U(V, W, N); U(V, W) and N.
Table 14 — Digital Tester
DIGITAL TESTER RESISTANCE VALUE DIGITAL TESTER RESISTANCE VALUE
(+)Red (-)Black
Several M
(+)Red (-)Black
Several M
P
NU
N
UV
VW
W-
Electricity remains in capacitors even when the power supply is off.
Ensure the capacitors are fully discharged before troubleshooting.