40MBFAQ: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
30
DIAGNOSIS AND SOLUTION (CONT.)
PC 0L (Low ambient temperature protection)
Description: This is a protection function. When the compressor is off, the outdoor ambient temperature(T4) is lower
than -31
F (-35
C) for 10s, the air conditioner stops and displays the failure code.
When the compressor is on, the outdoor ambient temperature(T4) is lower than -40F(-40C).for 10s, the air conditioner stops and displays a failure
code. When the outdoor ambient temperature (T4) is no lower than -25.6F (-32C) for 10s, the unit exits protection.
EC 0d(Outdoor unit malfunction Diagnosis and Solution)
Description: The indoor unit detect the outdoor unit is error.
Recommended parts to prepare:
• Outdoor unit
Troubleshooting
Is the main board
displaying an error?
WŽǁĞƌŽīƚŚĞŶƌĞƐƚĂƌƚƚŚĞƵŶŝƚƚǁŽ
ŵŝŶƵƚĞƐůĂƚĞƌŽĞƐƚŚĞŽƵƚĚŽŽƌŵĂŝŶ
board display an error code several
ŵŝŶƵƚĞƐůĂƚĞƌ
No
Yes
Refer to the prescribed steps
ƚŽƌĞƐŽůǀĞƚŚĞŝƐƐƵĞ
Yes