Installation Instructions
NOTE: Read the entire instruction manual before starting the 
installation.
SAFETY CONSIDERATIONS
Installing and servicing of heating and air conditioning equipment can be
hazardous  due  to  system  pressures  and  electrical  components.  Only
trained personnel should install or service heating and air conditioning
equipment. 
Untrained  personnel  can  perform  basic  maintenance  functions  such  as
cleaning  coils,  or  cleaning  and  replacing  filters. All  other  operations
should  be  performed  by  trained  personnel.  When  working  on  heating
and  air  conditioning  equipment,  observe  precautions  in  literature,  on
tags, and on labels attached to the unit.
Follow  all  safety  codes. Wear safety  glasses  and  work  gloves.  Have  a
fire extinguisher available.
Recognize safety information. This is the safety-alert symbol  . When
you see this symbol on the unit and in instructions or manuals, be alert to
the potential for personal injury. 
Understand  the  signal  words  DANGER,  WARNING,  and  CAUTION.
These words are used with the safety-alert symbol. DANGER identifies
the most serious hazards which will result in  severe personal injury  or
death.  WARNING  signifies  hazards  which  could  result  in  personal
injury or death.  CAUTION  is used  to  identify unsafe  practices, which
may  result  in  minor  personal  injury  or  product  and  property  damage.
NOTE  is  used  to  highlight  suggestions  which  will  result  in  enhanced
installation, reliability, or operation.
KFFEH
Electric Heater Packages
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before  beginning  any  installation  or  modification,  be  sure  the  main
electrical disconnect switch(es) is  in the OFF  position. There may  be
more  than  one  power  supply.  Tag  the  disconnect  switch(es)  with  a
suitable warning label.
Table 1 – EH Heater Table
HEATER 
PART NO.
kW 
@ 240V
VOLTS/PH
STAGES (kW 
OPERATING)
INTERNAL CIRCUIT 
PROTECTION
FAN COIL SIZE USED 
WITH
HEATING CAP.
*
 
@ 230V
*. Does not include heat from blower motor.
KFFEH8401N03 3 230/1 3 None
18
†
9,400
KFFEH8501N05 5 230/1 5 None
18
†
†. Size 18 fan coil has a special 6-pin connector. Do not modify wiring.
15,700
KFFEH8801N08 8 230/1 8 None
18
†
25,100
KFFEH8901N10 10 230/1 10 None
18
†
31,400
KFFEH0401N03 3 230/1 3 None 24 9,400
KFFEH0501N05 5 230/1 5 None 24–60 15,700
KFFEH0801N08 8 230/1 8 None 24–60 25,100
KFFEH0901N10 10 230/1 10 None 24–60 31,400
KFFEH3201F20 20 230/1 5, 20
Fuse
‡
‡. Single point wiring kit required for these heaters.
30–60 62,800
KFFEH8401C05 5 230/1 5 Circuit Breaker
18
†
15,700
KFFEH8501C08 8 230/1 8 Circuit Breaker
18
†
25,100
KFFEH8601C10 10 230/1 10 Circuit Breaker
18
†
31,400
KFFEH2401C05 5 230/1 5 Circuit Breaker 24–60 15,700
KFFEH2501C08 8 230/1 8 Circuit Breaker 24–60 25,100
KFFEH2601C10 10 230/1 10 Circuit Breaker 24–60 31,400
KFFEH3301C20 20 230/1 5, 20 Circuit Breaker 30–60 62,800
KFFEH2901N09 9
230/1
**
**. Field convertible to 3 phase.
3, 9 None 36–60 28,200
KFFEH3001F15 15 230/1 5, 15
Fuse
‡
24–60 47,100
KFFEH3101C15 15 230/1 5, 15 Circuit Breaker 24–60 47,100
3 Phase Only
KFFEH1601315 15 230/3 5, 15 None 36–60 47,100
KFFEH2001318 18 230/3 6, 12, 18 None 42–60 56,500
3 Phase, Factory Shipped (field convertible to single phase)
KFFEH3401F24 24 230/3 8, 16, 24 Fuse  48, 60 78,300
KFFEH3501F30 30 230/3 10, 20, 30 Fuse 48, 60 94,100