Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 20-40VMM001-02 Printed in U.S.A. Form 40VMM-4SI Pg 1 01-20 Replaces: 40VMM-3SI
Installation and Maintenance Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FAN CURVE CHARACTERISTICS . . . . . . . . . . . . . . . 6
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Step 1 — Unpack and Inspect Units . . . . . . . . . . . 11
Step 2 — Position the Unit . . . . . . . . . . . . . . . . . . . 11
Step 3 — Mount the Unit . . . . . . . . . . . . . . . . . . . . . 12
Step 4 — Connect Piping . . . . . . . . . . . . . . . . . . . . . 13
Step 5 — Complete Electrical Connections . . . . . 14
Step 6 — Position and Connect Controller . . . . . 17
ACB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Pre-Start Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Drain Pump and Drainage Test . . . . . . . . . . . . . . . 21
System Operation Check . . . . . . . . . . . . . . . . . . . . 21
MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
INDOOR UNIT ADDRESSING . . . . . . . . . . . . . . . . 22
Wireless Remote Controller (40VM900001) . . . . . 22
Non-Programmable Controller (40VM900002) . . . 22
Programmable Controller (40VM900003). . . . . . . 23
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . 24
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . 25
APPENDIX A DIP SWITCH SETTINGS . . . . . . . . 26
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions that may cause death, personal injury or
property damage. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this
product.
Follow all safety codes. Wear safety glasses, protective
clothing, and work gloves. Use quenching cloth for brazing
operations. Have fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local
building codes and the current editions of the National
Electrical Code (NEC) ANSI/NFPA (American National
Standards Institute/National Fire Protection Association) 70. In
Canada, refer to the current editions of the Canadian Electrical
Code CSA (Canadian Standards Association) C22.1.
Understand the signal words
DANGER, WARNING, and
CAUTION. DANGER identifies the most serious hazards,
which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal
injury or death. CAUTION is used to identify unsafe practices,
which would result in minor personal injury or product and
property damage.
Recognize safety information. This is the safety-alert
symbol ( ). When this symbol is displayed on the unit and in
instructions or manuals, be alert to the potential for personal
injury. Installing, starting up, and servicing equipment can be
hazardous due to system pressure, electrical components, and
equipment location.
WARNING
Electrical shock can cause personal injury and death. Shut
off all power to this equipment during installation. There
may be more than one disconnect switch. Tag all
disconnect locations to alert others not to restore power
until work is completed.
WARNING
When installing the equipment in a small space, provide
adequate measures to avoid refrigerant concentration
exceeding safety limits due to refrigerant leak. In case of
refrigerant leak during installation, ventilate the space
immediately. Failure to follow this procedure may lead to
personal injury.
WARNING
DO NOT USE TORCH to remove any component. System
contains oil and refrigerant under pressure.
To remove a component, wear protective gloves and
goggles and proceed as follows:
a. Shut off electrical power to unit.
b. Recover refrigerant to relieve all pressure from
system using high-pressure and low pressure ports.
c. Traces of vapor should be displaced with nitrogen
and work area should be well ventilated. Refrigerant
in contact with an open flame produces toxic gases.
d. Cut component connection tubing with tubing cutter
and remove component from unit. Use a pan to catch
any oil that may come out of the lines and as a gage
for how much oil to add to the system.
e. Carefully unsweat remaining tubing stubs when
necessary. Oil can ignite when exposed to torch
flame.
Failure to follow these procedures may result in personal
injury or death.
WARNING
The ducting for the 7K (40VMM007--3) and 9K
(40VMM009--3) models (supply and return air ducts) is
intended for use in one room only. Do not install
ductwork from a single unit to multiple rooms for these
two models.
40VMM007A-048A
Medium Static Duct Indoor Unit for
Variable Refrigerant Flow (VRF) Systems

Questions and Answers:

Carrier 40VMM007A Specifications

General IconGeneral
BrandCarrier
Model40VMM007A
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY CONSIDERATIONS

General Safety Warnings

General precautions for installation, service, and maintenance to prevent injury or death.

GENERAL

Unit Overview and Warranty

Describes the unit's features, intended use, and warranty conditions.

DIMENSIONS

Unit Dimensions and Specifications

Details the physical dimensions for various unit models and provides related figures.

FAN CURVE CHARACTERISTICS

Fan Performance Curves and Data

Presents fan performance curves and airflow rate data for different static pressures.

INSTALLATION

Unpack and Inspect Units

Instructions for unpacking, inspecting units for damage, and handling precautions.

Position the Unit

Guidelines for selecting and positioning the unit, including clearance and support requirements.

Mount the Unit

Details on how to mount the unit using hanger bolts, adjusting height, and securing it.

Connect Piping

Instructions for connecting condensate and refrigerant piping, including slope and torque specifications.

Complete Electrical Connections

Guidelines for making electrical connections, including wiring codes, voltage, and circuit ampacity.

Position and Connect Controller

Instructions for installing wired controllers, communication wiring, and extensions.

START-UP

Pre-Start Check

Pre-start checks to ensure proper installation before powering on the unit.

Drain Pump and Drainage Test

Procedure to test the condensate drain pump and ensure proper drainage.

System Operation Check

Steps to verify system operation in cooling/heating modes and check unit components.

MAINTENANCE

Periodic Maintenance Schedule

Details recommended maintenance tasks for 3, 6, and 12-month intervals.

INDOOR UNIT ADDRESSING

Wireless Remote Controller Addressing

How to set indoor unit addresses using the wireless remote controller.

Wired Controller Addressing

Procedures for setting indoor unit addresses using non-programmable and programmable wired controllers.

TROUBLESHOOTING

LED Display Indicators and Error Codes

Explains LED display indicators and lists error codes with their meanings.

Troubleshooting Guide

Lists common problems, their possible causes, and recommended solutions.

REPLACEMENT PARTS

Ordering Replacement Parts

Information on how to order replacement parts, including required unit information.

APPENDIX A - DIP SWITCH SETTINGS

DIP Switch Configuration

Details the function of DIP switches for startup, mode, and indoor unit identification.