82
System Heating Performance Data (Cont.)
Ducted Split System
53QDMT42-518 Heat Pump
380-420V/3Ph/50Hz
Indoor Conditions Outdoor Ambient Temperature
ESP
in.wg
Fan
Speed
Air
Flow
cfm
Temp. °C
DB
24/18°C DB/WB 7/6°C DB/WB 2/1°C DB/WB
Capacity
Btu/hr
Input
W
Capacity
Btu/hr
Input
W
Capacity
Btu/hr
Input
W
0.20
in.wg
High
1187
15°C
49845 3265 40260 2810 32980 2415
20°C 48315 3555 38345 3015 31060 2655
27°C 45240 3780 36045 3260 29140 2870
Medium 1077
15°C
47350 3130 38245 2700 31335 2320
20°C 45900 3415 36430 2900 29510 2555
27°C 42985 3630 34245 3130 27690 2760
Low 491
15°C
43095 2885 34805 2485 28515 2135
20°C 41770 3145 33155 2670 26850 2345
27°C 39115 3340 31165 2880 25195 2540
0.24
in.wg
High
1151
15°C
49160 3250 39710 2795 32525 2410
20°C 47650 3540 37820 3000 30635 2645
27°C 44625 3760 35545 3240 28745 2855
Medium 1041
15°C
46705 3125 37725 2685 30900 2315
20°C 45275 3400 35930 2885 29105 2545
27°C 42395 3610 33770 3115 27310 2745
Low 434
15°C
42505 2870 34335 2470 28120 2130
20°C 41200 3130 32700 2655 26485 2340
27°C 38580 3325 30730 2860 24850 2525
0.28
in.wg
High
1115
15°C
48475 3230 39160 2780 32070 2395
20°C 46990 3520 37295 2985 30210 2630
27°C 44005 3735 35055 3220 28345 2840
Medium 1005
15°C
46055 3105 37205 2670 30470 2300
20°C 44645 3380 35430 2870 28700 2530
27°C 41810 3590 33305 3095 26930 2725
Low 377
15°C
41915 2850 33860 2455 27725 2120
20°C 40625 3110 32245 2640 26120 2325
27°C 38045 3300 30305 2845 24510 2510
0.32
in.wg
High
1079
15°C
47800 3210 38605 2765 31625 2380
20°C 46325 3500 36765 2975 29780 2615
27°C 43385 3710 34565 3200 27945 2820
Medium 969
15°C
45410 3085 36680 2660 30045 2285
20°C 44010 3365 34930 2855 28295 2515
27°C 41220 3565 32835 3075 26550 2705
Low 320
15°C
41325 2840 33375 2445 27340 2105
20°C 40050 3095 31785 2630 25750 2310
27°C 37510 3280 29885 2830 24165 2490
42QDMT42-718