Features quiet operation with minimum sound levels, achieved through vibration dampening.
Offers standard smart control with complete control functions via wired or wireless remote.
Ensures efficient tropical operation with minimum electrical consumption via a high-efficiency compressor.
Features compact dimensions, low height, and lightweight design for easy installation in ceilings.
Designed for easy installation, service, and maintenance with accessible components and features.
Equipped with a smart self-diagnostic function to automatically stop operation during malfunctions.
Incorporates sensitive sensors for refrigerant leak detection on indoor and outdoor coils.
Features like removable filters and accessible motors/fans simplify maintenance.
Lists export heat pump models, including system, indoor/outdoor units, and compressor details.
Lists domestic heat pump models with system, indoor/outdoor units, and compressor specifications.
Details dimensions and weights for ducted indoor units across various sizes.
Provides dimensions and weights for outdoor units of different models.
Details specifications for the compressor, including model, type, brand, and capacity.
Provides specs for indoor/outdoor fan motors, indoor/outdoor coils, and refrigerant piping.
Specifies control type, operation temperatures, and ambient temperature limits.
Illustrates the refrigeration cycle for a specific ducted split system heat pump model.
Presents air flow data against external static pressure for the 42QDMT12 model.
Provides air flow data against external static pressure for the 42QDMT24 model.
Continues air flow data against external static pressure for the 42QDMT36 model.
Presents air flow data against external static pressure for the 42QDMT42 model.
Details sound pressure levels for ducted indoor units at various speeds and ESPs.
Lists sound pressure levels for outdoor units for different models.
Provides cooling performance data for the 53QDMT12-718 model at various conditions.
Continues cooling performance data for the 53QDMT18-718 model.
Continues cooling performance data for the 53QDMT24-718 model.
Continues cooling performance data for the 53QDMT30-718 model.
Continues cooling performance data for the 53QDMT36-718 model.
Continues cooling performance data for the 53QDMT42-718 model.
Provides cooling performance data for the 53QDMT42-518 model.
Continues cooling performance data for the 53QDMT48-518 model.
Continues cooling performance data for the 53QDMT60-518 model.
Provides heating performance data for the 53QDMT12-718 model at various conditions.
Continues heating performance data for the 53QDMT18-718 model.
Continues heating performance data for the 53QDMT24-718 model.
Continues heating performance data for the 53QDMT30-718 model.
Continues heating performance data for the 53QDMT36-718 model.
Continues heating performance data for the 53QDMT42-718 model.
Provides heating performance data for the 53QDMT42-518 model.
Continues heating performance data for the 53QDMT48-518 model.
Continues heating performance data for the 53QDMT60-518 model.
Details electrical consumption (Amp, Watt) for cooling across various outdoor temperatures.
Details electrical consumption (Amp, Watt) for heating across various outdoor temperatures.
Specifies the required circuit breaker rating (Amp) for each model.
Shows the electrical wiring diagram for the 53QDMT12-718 and 53QDMT18-718 heat pump models.
Illustrates the field electrical wiring connection for outdoor and indoor units.
Displays wiring diagrams for 53QDMT24-718, 53QDMT30-718, 53QDMT36-718, 53QDMT42-718.
Shows wiring diagrams for 380-420V heat pump models, covering 36K to 60K series.
Depicts field electrical wiring for 380-420V outdoor and indoor units.
Describes a branched supply air front panel for flexible duct installation and improved air distribution.
Shows the shapes and dimensions of branched supply air front panels for various indoor unit sizes.
Details the shape and dimensions of canvas air passages for different indoor unit sizes.
Lists parts and quantities for the front panel of a 12K ducted indoor unit.
Lists parts and quantities for the front panel of an 18K ducted indoor unit.
Lists parts and quantities for the front panel of a 24K ducted indoor unit.
Lists parts and quantities for front panels of larger ducted indoor units (30K-60K).
Troubleshooting steps for common indoor unit malfunctions like sensor errors.
Troubleshooting steps for common issues with outdoor unit power, EEPROM, and water level.
Troubleshooting steps for outdoor unit protection, phase errors, overload, and sensor faults.
Provides a table of sensor resistance values to aid in diagnosing sensor issues.