DUCT TYPE AIR CONDITIONER
INSTALLATION MANUAL
IMROPTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit.
Make sure to save this manual for future reference.
Please check the applicable models, F-GAS and manufacturer information from the
“Owner's Manual - Product Fiche” in the packaging of the outdoor unit.
(European Union products only)
NORSK
SVENSKA
LATVIJAS
ESTS
LIETUVOS
DANSK
PORTUGUÊS
MANUAL DE INSTALAÇÃO
P T

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier 42QSS009DS series and is the answer not in the manual?

Carrier 42QSS009DS series Specifications

General IconGeneral
BrandCarrier
Model42QSS009DS series
CategoryAir Conditioner
LanguageEnglish

Summary

Preparing For Installation

Safety Precautions

Details crucial safety measures to be followed during installation and servicing of air conditioning equipment.

Indoor Unit Installation

Install Drain Pipe

Detailed steps for installing the drain pipe, including connections and drainage tests for units with and without pumps.

Outdoor Unit Installation

Installation Site Choosing

Criteria for selecting an appropriate installation location for the outdoor unit, considering ventilation and environment.

Install The Outdoor Unit

Steps for securely installing the outdoor unit onto its base, ensuring strength and horizontality.

Refrigerant Piping Work

Flaring

Detailed steps and tools required for flaring refrigerant pipes, including dimension checks and common errors.

Piping Work

Instructions for connecting refrigerant pipes, including alignment, tightening torque, and insulation material selection.

Air Evacuation

Procedure for evacuating air from the refrigerant system using a vacuum pump and manifold gauge.

Leakage Test

Methods for testing refrigerant piping connections for leaks using soapy water or a leak detector.

Wiring

Final Check and Trial Operation

Trial Operation

Steps for conducting a trial operation of the indoor and outdoor units to verify functionality and identify issues.

Information Servicing

Leak Detection Methods

Acceptable methods for detecting leaks in systems with flammable refrigerants, including detector calibration.

Removal And Evacuation

Procedures for safely removing and evacuating refrigerant from the system before repairs or decommissioning.

Charging Procedures

Requirements for charging refrigerant systems, including contamination control and system earthing.

Recovery

Best practices for safely recovering refrigerants, including cylinder handling and equipment checks.