GB-10
3. OUTDOOR UNIT INSTALLATION
3.1 INSTALLATION SITE CHOOSING
OUTDOOR UNIT
■ Where it is out of rain or direct sunlight.
■ Where it is well-ventilated and free from obstacles near the air inlet and air outlet.
■ Where does not increase the operating noise or vibration of the outdoor unit.
■ Where does not cause any drainage problem with discharged water.
■ Install the outdoor unit properly at a place that is durable enough to the weight of the outdoor unit.
■ Where provides appropriate clearances as outlined
■ Where the piping between the indoor and outdoor units is within the allowable limits.
■ In regions with snowfall and cold temperatures, avoid installing the outdoor unit in areas where it can be covered by
snow. If heavy snow is expected, a field supplied ice or stand and field supplied-installed wind baffle should be
installed to protect the unit from snow accumulation and blocked air intake.
■ When installing the outdoor unit in a place that is
constantly exposed to a strong wind, it is recommended
that a wind baffle be used.
X
O
Strong wind
3.2 OUTDOOR UNIT MOUNTING DIMENSION
W
H
mmmm
W
H
B
A
D
Outline dimension
845 700 320 335
WHD A B
945 810 395 405
938 1369 392 404
024
036
048/060
810 558 310 325
018
560
640
634
549
Model
(38QUS)