– 5 –
FILE NO. SVM-05010
MODEL
42HNR024-713
42HNR018-713
38HNR024-713
38HNR018-713
ITEM
Cooling
Heating Cooling
Heating
Capacity kW
220 V
240 V
220 V
240 V
220 V
240 V
220 V
240 V
6.30
6.30
6.80
6.90 5.05
5.05
5.80
5.90
Phase ∅1
Power source V 220 − 240
Hz 50
Power consumption W
2430
2510
2390
2490
1920
2040
1800
1950
Power factor %
96
92
94
90
95
88
94
86
220 V
240 V
220 V
240 V
220 V
240 V
220 V
240 V
Running current A
0.3/
0.3/
0.3/
0.3/
0.2/
0.2/
0.2/
0.2/
Indoor/Outdoor
11.2
11.1
11.2
11.28
9.0
9.5
8.5
9.3
Starting current A
60
45
Moisture removal lit/h
2.5
2.0
Noise
Indoor (H/M/L) dB 45/41/37 42/39/35
Outdoor (220 − 240 V) dB
56-57
57-58
52-53 53-54
Refrigerant
Name of refrigerant R22
Rated amount kg 1.75
1.17
Refrigerant control Capillary tube
Gas side size mm ∅15.88 ∅12.7
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection Connection type Flare connection
pipe Maximum length
m
15*
1
(One way) 25*
2
20*
2
Maximum height
10 8
difference
INDOOR UNIT
42HNR024-713 42HNR018-713
Height mm 298
Dimensions Width mm 998
Depth mm 220
Net weight kg 13
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 900
750
800
Air volume Medium fan m
3
/h 750
790
667
708
Low fan m
3
/h 625
667
543
584
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT
38HNR024-713 38HNR018-713
Height mm 690 538
Dimensions Width mm 880 830
Depth mm 310 300
Net weight kg
61 54
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h
3380
3560
2105 2310
Fan motor output W
65
Compressor
Model
2JS386D5BB02
2JS350D5A02
Output W
1800
1700
Safety device
IOL, Td Sensor IOL, Td Sensor
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43
−10 ~ 24
21 ~ 43 −10 ~ 24
m
298
998
208
13
Note
*1 Chargeless pipe
*2 Maximum pipe