EasyManua.ls Logo

Carrier 48TC series - Features and Benefits; High

Carrier 48TC series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
FEATURES AND BENEFITS
S Single cooling stage models are available from 3 -- 10 ton.
S Two cooling stage models are available from 7.5 -- 15 ton.
S SEER up to 13.0.
S EER’s up to 11.1.
S IEER’s up to 11.8 with single speed indoor fa n motor and up to 12.8 with 2--speed/VFD indoor fan motor.
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time and
money on replacement jobs.
S Standardize d compone nts and layout. Standardized compone nts and controls make service a nd stocking parts easier.
S Scroll compressors on all units. Thi s makes service, stocking parts, replacement, and t roubleshooting easier.
S Field convertible airflow (3 -- 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to
overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical
to horizontal.
S Easy-- adjust, belt--drive motor available.
S Provisions for bottom or side condensat e drai n.
S Capable of thru--the--base or thru--the--curb gas line routing.
S Single--point gas / electrical connection.
S Sloped, composite dra in pan sheds water; and won’t rust.
S Standardize d control s & control box layout. Standardized components & controls make stocking parts & service easier.
S Tool --less filter access door.
S Clean, large, easy to use cont rol box.
S Color--coded wiring.
S Large, lam inate d wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
S Single, central term inal board for test and wiring connections.
S Fast--access, handled, panels for easy access on normally accessed service panels.
S “No--strip” screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or
the unit.
S Mechanical cooling (115_Fto40_For46_Cto4_C) standard on all models. Winter Start Kit allows cooling operation
downto25_F(--4_ C) and MotorMaster to --20_F(--29_C).
S High efficiency, gas heat with induced--draft flue exhaust design.
S Induced draft motor ensures no flue gas can escape into the indoor air stream.
S Carrier designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be
periodicall y, manually drained. This saves la bor and maintenance expense.
S 2 --in (51mm) disposable filters on all units.
S Refrigerant filter --drier on each circuit.
S Each circuit is protected with a high and low pressure switch.
S Many factory--installed options ranging from air management economizers, 2 position dampers, plus convenience
outlets, disconnect switches and smoke detectors.
S Standard (parts only) Warranty: 10 yr. alum inize d heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr.
parts.
S Factory--installed Humidi--MiZerr
adapt ive dehumidification system on all sizes with round tube / plate fin condenser
coils, includes MotorMaster I controller.
S Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor
fan motor speed between cooling stages. Available on 2--stage cooling models 08--16 with electromechani cal controls or
RTU Open.

Related product manuals