EasyManua.ls Logo

Carrier 50EZ-A30 User Manual

Carrier 50EZ-A30
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
50EZ ---A
Comfortt 13 SEER Single ---P ackaged Heat Pump
System with Puron (R---410A) Refrigerant
Three Phase
2 1 / 2 --- 5 N o m i n a l To n s ( S i z e s 3 0 --- 6 0 )
Installation Instructions
IMPORTANT: Effective January 1, 2015, all split system and
packaged air conditioners must be installed pursuant to applicable
regional efficiency standards issued by the Department of Energy.
NOTE: Read the entire instruction manual before starting the
installation.
NOTE: Installer: Make sure the Owner’s Manual and Service
Instructions are left with the unit after installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1 --2.......................
INTRODUCTION 2...................................
RECEIVING AND INSTALLATION 2--9..................
Check Equipment 2..................................
Identify Unit 2....................................
Inspect Shipment 2.................................
Provide Unit Support 2...............................
Roof Curb 2......................................
Slab Mount 2.....................................
Provide Clearances 2.................................
Rig and Place Unit 3.................................
Inspection 3......................................
Rigging/Lifting of Unit 7............................
Select and Install Ductwork 7...........................
Converting Horizontal Discharge Units to Downflow
(Vertical) Discharge Units 8..........................
Provide for Condensate Disposal 9......................
Install Electrical Connections 9.........................
High--Voltage Connections 9.........................
Special Procedures for 208--V Operation 10..............
Control Voltage Connections 10.......................
Standard Connections 10............................
Transformer Protection 10...........................
Accessory Electric heaters Installation 10................
PRE--START --UP 18...................................
START--UP 18--24.....................................
Checking Cooling & Heating Control Operation 18........
Check for Refrigerant Leaks 18.........................
Start-- Up Adjustments 18.............................
50EZ--A Sequence of Operation 19....................
Checking & Adjusting Refrigerant Charge 19............
Indoor Airflow & Airflow Adjustments 19..............
Continuous Fan Operation 20........................
Defrost Control 28...................................
Quiet Shift 28.....................................
Defrost 28.......................................
MAINTENANCE 28--3 3................................
Air Filter 28........................................
Indoor Blower and Motor 28...........................
Outdoor Coil, Indoor Coil, & Condensate Drain Pan 29......
Outdoor Fan 29.....................................
Electrical Controls and Wiring 31.......................
Refrigerant Circuit 31.................................
Indoor Airflow 32...................................
A09034
Fig. 1 -- Unit 50EZ-- A
Metering Devices-- TXV & Piston 32....................
Pressure Switches 32.................................
Loss of Charge Switch 32.............................
High Pressure Switch 32..............................
Copeland Scroll compressor (Puron Refrigerant) 32.........
Refrigerant System 32................................
Refrigerant 32....................................
Compressor Oil 32.................................
Servicing Systems on Roofs with Synthetic Materials 32....
Liquid Line Filter Drier 33...........................
PuronR (R--410A) Refrigerant Charging 33.............
System Information 33................................
Loss of Charge Switch 33............................
Check Defrost Thermostat 33.........................
TROUBLESHOOTING 33..............................
START--UP CHECKLIST 33............................
SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due
to mechanical and electrical components. Only trained and
qualified personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning and replacing air filters. All other operations must be
performed by trained service personnel. When working on this
equipment, observe precautions in the literature, on tags, and on
labels attached to or shipped with the unit and other safety
precautions that may apply.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes, the
current editions of the National Electrical Code (NEC) NFPA 70.
In Canada refer to the current editions of the Canadian electrical
Code CSA C22.1.
Recognize safety information. This is the safety-- alert symbol
.
When you see this symbol on the unit and in instructions or manu-
Question and Answer IconNeed help?

Do you have a question about the Carrier 50EZ-A30 and is the answer not in the manual?

Carrier 50EZ-A30 Specifications

General IconGeneral
EER11.0
Voltage208/230 V
Phase1
Hertz60 Hz
RefrigerantR-410A
Power Supply208/230V, 1 Phase, 60 Hz

Summary

Receiving and Installation

Check Equipment

Verifying unit model and serial number against shipping papers.

Inspect Shipment

Inspecting for shipping damage and reporting any issues.

Provide Unit Support

Instructions for roof curb or slab mount installation.

Rig and Place Unit

Procedures for safely rigging and placing the unit.

Select and Install Ductwork

Guidelines for selecting and installing duct systems.

Install Electrical Connections

Procedures for making electrical connections.

Pre-Start-Up and Start-Up Procedures

Checking Cooling and Heating Control Operation

Verifying proper operation of thermostat and unit controls.

Check for Refrigerant Leaks

Procedures for identifying and repairing refrigerant leaks.

Start-Up Adjustments

Steps to complete before operating the unit.

Checking and Adjusting Refrigerant Charge

Methods for verifying and adjusting refrigerant charge.

Indoor Airflow and Airflow Adjustments

Checking and adjusting airflow for optimal unit performance.

Maintenance

Air Filter

Instructions for inspecting, cleaning, or replacing air filters.

Outdoor Coil, Indoor Coil, and Condensate Drain Pan

Procedures for cleaning coils and drain pan.

Outdoor Fan

Maintenance steps for the outdoor fan assembly.

Refrigerant System

Copeland Scroll Compressor

Information and warnings about the specific compressor model.

Refrigerant System Components

Covers compressor oil, synthetic roof precautions, and filter driers.

Loss of Charge Switch

Explains the function and troubleshooting of the loss of charge switch.

Check Defrost Thermostat

Details on how the defrost thermostat functions and is checked.

Puron (R-410A) Refrigerant Guide

Essential guide for handling Puron refrigerant and associated components.

Related product manuals