14
Performance data (cont)-Standard PSC indoor motor
COOLING EXTENDED PERFORMANCE TABLE
HEATING EXTENDED PERFORMANCE TABLE -10–20
HEATING EXTENDED PERFORMANCE TABLE 30–60
*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 17.
50JZ042 COOLING PERFORMANCE TABLE
Temp (F)
Outdoor Air
Entering
Condenser
Evaporator Air—CFM/BF
1225/0.11 1400/0.12 1575/0.14
Evaporator Air — Ewb (F)
62 63* 67 72 62 63* 67 72 62 63* 67 72
75
TC 41.2 41.9 44.8 47.0 42.5 43.0 45.7 47.6 43.3 43.7 46.1 48.0
SHC 37.4 30.5 31.4 24.8 40.2 32.5 33.3 25.8 42.2 34.2 34.6 26.5
kW 3.08 3.13 3.10 3.11 3.09 3.14 3.11 3.12 3.10 3.14 3.11 3.13
85
TC 39.1 39.8 42.9 45.9 40.3 40.9 43.9 46.5 41.3 41.5 44.4 46.8
SHC 36.3 29.5 30.8 24.3 39.1 31.5 32.8 25.3 40.8 33.3 34.1 26.1
kW 3.39 3.45 3.42 3.44 3.41 3.47 3.42 3.44 3.42 3.47 3.46 3.45
95
TC 36.0 37.5 40.7 44.0 38.1 38.5 41.7 44.5 39.3 39.2 42.2 44.7
SHC 34.4 28.4 29.8 23.6 38.1 30.4 31.8 24.6 39.3 32.2 33.5 25.5
kW 3.68 3.79 3.76 3.81 3.75 3.81 3.76 3.82 3.76 3.81 3.76 3.81
105
TC 32.9 33.8 36.9 39.6 34.5 34.6 37.9 40.1 35.8 35.2 38.2 40.5
SHC 31.9 26.2 27.8 21.6 34.5 28.1 29.9 22.7 35.8 29.8 31.3 23.5
kW 4.16 4.25 4.21 4.22 4.20 4.27 4.20 4.23 4.20 4.27 4.20 4.23
115
TC 30.9 31.2 33.7 36.4 32.2 31.8 34.4 36.9 33.2 32.3 34.9 37.1
SHC 30.4 25.1 26.2 20.3 32.2 26.7 28.1 21.3 33.2 28.3 29.6 22.1
kW 4.59 4.68 4.61 4.62 4.62 4.68 4.61 4.63 4.61 4.68 4.60 4.63
125
TC 28.6 28.2 30.5 32.8 29.6 28.8 31.1 33.2 30.5 29.3 31.5 33.4
SHC 28.2 23.4 24.7 18.8 29.6 25.2 26.5 19.7 30.5 27.1 27.9 20.4
kW 5.07 5.20 5.07 5.08 5.08 5.16 5.06 5.09 5.07 5.11 5.06 5.09
50JZ042
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
-100 101720
60
1225
TC
11.6
9.9 15.6 13.3 19.6 18.0 22.7 20.7 24.3 21.9
kW
2.36 2.51 2.67
2.78 2.82
1400
TC
11.9
10.1 15.9 13.5 19.9 18.3 23.2 21.1 24.7 22.3
kW
2.39 2.53 2.67 2.78 2.82
1575
TC
12.1
10.3 16.2 13.8 20.2 18.6 23.5 21.4 25.1 22.6
kW
2.42 2.55 2.69 2.79 2.83
70
1225
TC
10.9
9.3 14.9 12.7 18.9 17.4 22.0 20.1 23.6 21.3
kW
2.59 2.77 2.94
3.06 3.11
1400
TC
11.2
9.6 15.3 13.0 19.3 17.7 22.4 20.4 24.0 21.6
kW
2.62 2.78 2.94 3.05 3.10
1575
TC
11.5
9.8 15.5 13.2 19.6 18.0 22.7 20.7 24.3 21.9
kW
2.65 2.80 2.95 3.06 3.10
80
1225
TC
10.1
8.6 14.2 12.0 18.2 16.7 21.3 19.5 22.9 20.6
kW
2.86 3.05 3.23
3.37 3.43
1400
TC
10.4
8.9 14.5 12.3 18.6 17.1 21.7 10.8 23.3 21.0
kW
2.88 3.06 3.23 3.36 3.42
1575
TC
10.7
9.1 14.8 12.6 18.9 17.4 22.1 20.1 23.7 21.3
kW
2.92 3.08 3.24 3.36 3.41
50JZ042
Return
Air (F db)
CFM (Standard Air)
Air Temperature Entering Outdoor Coil (F db at 70% rh)
30 40 47 50 60
60
1225
TC
29.5
25.9 35.4 35.4 40.3 40.3 41.9 41.9 48.0 48.0
kW
2.97 3.16 3.32
3.38 3.60
1400
TC
30.0
26.3 35.9 35.9 40.7 40.7 42.4 42.4 48.6 48.6
kW
2.95 3.14 3.29 3.34 3.53
1575
TC
30.3
26.6 36.3 36.3 40.8 40.8 42.3 42.3 48.3 48.3
kW
2.95 3.12 3.26 3.31 3.48
70
1225
TC
28.9
25.3 34.5 34.5 39.6 39.6 41.3 41.3 48.1 48.1
kW
3.29 3.49 3.69
3.74 4.01
1400
TC
29.3
25.7 35.0 35.0 40.1 40.1 42.0 42.0 48.5 48.5
kW
3.26 3.45 3.62 3.70 3.92
1575
TC
29.7
26.0 35.4 35.4 40.5 40.5 42.0 42.0 48.1 48.1
kW
3.26 3.44 3.60 3.65 3.85
80
1225
TC
27.9
24.5 33.8 33.8 38.6 38.6 40.3 40.3 47.5 47.5
kW
3.63 3.87 4.06
4.13 4.45
1400
TC
28.5
24.9 34.2 34.2 39.2 39.2 40.9 40.9 47.7 47.7
kW
3.61 3.82 4.00 4.06 4.33
1575
TC
29.0
25.4 34.6 34.6 39.6 39.6 41.3 41.3 47.7 47.7
kW
3.59 3.79 3.96 4.02 4.26