APPENDIX A — MODEL NUMBER SIGNIFICANCE
Fig. A — Model Number Nomenclature
5 0 K C - A 0 4 A 0 A 5 - 0 A 0 A 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Unit Heat Type
50 – Cooling with
Electric Heat
Series/Model
KC – 14 SEER Efficiency
Heat Size
— – No Heat
Refrig. Systems Options
A – Standard One-Stage Cooling Models
B – Standard One-Stage Cooling Models
with Humidi-MiZer
Cooling Tons
04 – 3 ton
05 – 4 ton
06 – 5 ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch (electromech controls only)
K = Condensate Overflow Switch and RA Smoke Detectors
L = Condensate Overflow Switch and RA + SA Smoke
Detectors
Indoor Fan Options
0 = Direct Drive X13 Motor
2 = Medium Static Option – Belt Drive
3 = High Static Option – Belt Drive
Note: On single phase (-3 voltage code) models, the following
are not available as a factory-installed option:
– Humidi-MiZer
– Coated Coils or Cu Fin Coils
– Louvered Hail Guards
– Economizer or 2-Position Damper
– Powered 115 volt Convenience Outlet
Packaging and Seismic Compliant
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-the-Base Connections
F = Non-Fused Disconnect and Thru-the-Base
Connections
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels, Unpowered Convenience Outlet
5 = Hinged Panels, Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temp Ultra Low Leak Economizer w/ Baro Relief
W = Enthalpy Ultra Low Leak Econo w/ Baro Relief
Base unit controls
0 = Electromechanical Controls, can be used with W7212
EconoMi$er IV (Non-Fault Detection and Diagnostic)
1 = PremierLink Controller
2 = RTU Open Multi-Protocol Controller
6 = Electromechanical, can be used with W7220 EconoMi$er X
(with Fault Detection and Diagnostic)
Design Revision
Factory Assigned
Voltage
1 = 575/3/60 5 = 208-230/3/60
3 = 208-230/1/60 6 = 460/3/60
Coil Options (outdoor – indoor – hailguard)
A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guards
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guards
P = E-coat Al/Cu –Al/Cu – Louvered Hail Guards
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guards
R = Cu/Cu – Al/Cu – Louvered Hail Guards
S = Cu/Cu – Cu/Cu – Louvered Hail Guards